The Accuracy of the Titan 1+ 10 Hz Global Positioning System for Measures of Time, Distance, and Top Speed

Introduction: Global Positioning System (GPS) technology provide quantifiable data concerning the number and types of movements athletes complete across training session and match player. The Titan 1+ is a novel GPS device that has not been investigated to establish measures of accuracy or reliability. The purpose of this study was to establish device accuracy for metrics including distance, top speed, and time between the Titan 1+ 10 Hz GPS device and criterion measures. Criterion measures include tape measure, stopwatch, and radar gun for measures of distance, time, and top speed, respectively. Methods and Materials: 16 male NCAA collegiate soccer players completed running protocols of varying distances and speeds, including long and short duration straight-line running (100m Run and SLR), tight and gradual change of direction running (COD T and COD G), and a team-sport simulated circuit. Results: The Titan 1+ was not significantly different from tape measured distance during the SLR protocol for 10m jog and all movements speed across 20m and 40m (p < .05). The Titan 1+ was significantly correlated to radar gun top speed measures for all distances and movement speeds during the SLR (p < .01). The Titan 1+ was significantly different from the stopwatch for measures of time accuracy (p < .0001), however significant correlations were identified for all jogging distances (p < .01), the 20m and 40m strides (p < .01), and the 10m sprint (p < .01). COD G and COD T distances were accurately measured between the Titan 1+ and tape measure (p < .05). The Titan 1+ revealed correlations for time measures during jogging and striding during the COD G (p = .001 and p < .0001) and during the COD T (p < .0001 and p< .0001). Device accuracy was established for measure of time during the TSSC (p < .05), with time measures significantly correlated between the Titan 1+ and stopwatch (p < .01). Top speed for the TSSC was significantly different between the radar gun and Titan 1+ device (p = .001), but both devices were significantly correlated (p < .01). Conclusions: The results of the present study indicate that the Titan 1+ demonstrates accurate measures of time, distance, and top speed when compared to criterion measures.

Authors

Institutions

Publication Details

Journal
International Journal of Strength and Conditioning
Published
2024-10-18
DOI
https://doi.org/10.47206/ijsc.v4i1.326
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Accuracy of the Titan 1+ 10 Hz Global Positioning System for Measures of Time, Distance, and Top Speed

Kevin Neeld, Victoria Elia, Mark E. Harmon, Thomas Cappaert
International Journal of Strength and Conditioning
Advanced Frequency and Time Standards
article

The Accuracy of the Titan 1+ 10 Hz Global Positioning System for Measures of Time, Distance, and Top Speed

Kevin Neeld, Victoria Elia, Mark E. Harmon, Thomas Cappaert
article en

Abstract

Introduction: Global Positioning System (GPS) technology provide quantifiable data concerning the number and types of movements athletes complete across training session and match player. The Titan 1+ is a novel GPS device that has not been investigated to establish measures of accuracy or reliability. The purpose of this study was to establish device accuracy for metrics including distance, top speed, and time between the Titan 1+ 10 Hz GPS device and criterion measures. Criterion measures include tape measure, stopwatch, and radar gun for measures of distance, time, and top speed, respectively. Methods and Materials: 16 male NCAA collegiate soccer players completed running protocols of varying distances and speeds, including long and short duration straight-line running (100m Run and SLR), tight and gradual change of direction running (COD T and COD G), and a team-sport simulated circuit. Results: The Titan 1+ was not significantly different from tape measured distance during the SLR protocol for 10m jog and all movements speed across 20m and 40m (p < .05). The Titan 1+ was significantly correlated to radar gun top speed measures for all distances and movement speeds during the SLR (p < .01). The Titan 1+ was significantly different from the stopwatch for measures of time accuracy (p < .0001), however significant correlations were identified for all jogging distances (p < .01), the 20m and 40m strides (p < .01), and the 10m sprint (p < .01). COD G and COD T distances were accurately measured between the Titan 1+ and tape measure (p < .05). The Titan 1+ revealed correlations for time measures during jogging and striding during the COD G (p = .001 and p < .0001) and during the COD T (p < .0001 and p< .0001). Device accuracy was established for measure of time during the TSSC (p < .05), with time measures significantly correlated between the Titan 1+ and stopwatch (p < .01). Top speed for the TSSC was significantly different between the radar gun and Titan 1+ device (p = .001), but both devices were significantly correlated (p < .01). Conclusions: The results of the present study indicate that the Titan 1+ demonstrates accurate measures of time, distance, and top speed when compared to criterion measures.

International Journal of Strength and ConditioningVol. 4(1)
Tulane University (US), Rocky Mountain University of Health Professions (US)
Openalex Percentile: Top 83%
Advanced Frequency and Time Standards
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.