Turbidity and color removal from irrigation water, with coagulants and activated carbon, controlled by an Arduino system

The Moche River water is contaminated due to informal mining and other anthropogenic activities. The pollutants are primarily organic matter and heavy metals, which contribute to the water's elevated color and turbidity levels. This contaminated water is used for irrigating surrounding areas, leading to the production of contaminated crops. Monitoring color and turbidity requires expensive instruments. In this study, a water sample was collected from the district of Poroto, located in the province of Trujillo, La Libertad region. Approximately 200 L were sampled, with a pH of 5.2 and a turbidity of 12.04 NTU. The research employs a combined treatment process involving coagulants, specifically ferric sulfate and polyaluminum chloride, followed by filtration through activated carbon. Additionally, a low-cost monitoring system using an Arduino-based turbidimeter and colorimeter is proposed to measure water quality before and after treatment. The system incorporates a TS-300B turbidity sensor and a custom-built Arduino colorimeter utilizing the BPW34 sensor. Experimental results show a maximum color removal efficiency of 95.71% and a turbidity reduction of 70.43% under optimal conditions. The activated carbon used had the following properties: an iodine number of 902.85 mg/g, 10.73 mmol of acidic groups, and a point of zero charge (PZC) of 9.3. The turbidimeter and colorimeter cost $40.46 and $58.15, respectively. Validation parameters for the instruments were as follows: Pearson correlation coefficient of 99.98%, MAE of 2.46, RMSE of 3.80, and MAPE of 2.18% for the turbidimeter, and Pearson correlation coefficient of 99.73%, MAE of 0.07, RMSE of 0.08, and MAPE of 9.44 % for the colorimeter. This innovative solution demonstrates the feasibility of using low-cost technology for effective water treatment, contributing to sustainable agricultural practices by improving irrigation water quality and promoting better crop health and environmental protection. • Implementation of an automated monitoring system with Arduino to control the removal of turbidity and color in irrigation water. • Use of coagulants (ferric sulfate and polyvinyl chloride) and activated carbon to improve the water quality of the Moche River. • The Arduino system measures and validates turbidity and color in real time using sensors calibrated with commercial equipment. • Maximum color removal of 95.71% and turbidity of 70.43% was achieved at optimal recirculation times. • The system is affordable, economical and efficient for implementation in large-scale water treatment studies.

Authors

Institutions

Publication Details

Journal
Case Studies in Chemical and Environmental Engineering
Published
2024-10-18
DOI
https://doi.org/10.1016/j.cscee.2024.100978
Citations
2
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Turbidity and color removal from irrigation water, with coagulants and activated carbon, controlled by an Arduino system

Adolfo Enrique Guerrero Escobedo, Ronald Fernando Rodríguez Espinoza, Yrwin Francisco Azabache Liza, Juan Manuel Ipanaqué Roña et al.
2 citations
Case Studies in Chemical and Environmental Engineering
Water Quality Monitoring Technologies
0.40
article

Turbidity and color removal from irrigation water, with coagulants and activated carbon, controlled by an Arduino system

Adolfo Enrique Guerrero Escobedo, Ronald Fernando Rodríguez Espinoza, Yrwin Francisco Azabache Liza, Juan Manuel Ipanaqué Roña, Christian Xavier Meregildo Collave, Robert Jefferson Lázaro Bacilio
article en
2 citations

Abstract

The Moche River water is contaminated due to informal mining and other anthropogenic activities. The pollutants are primarily organic matter and heavy metals, which contribute to the water's elevated color and turbidity levels. This contaminated water is used for irrigating surrounding areas, leading to the production of contaminated crops. Monitoring color and turbidity requires expensive instruments. In this study, a water sample was collected from the district of Poroto, located in the province of Trujillo, La Libertad region. Approximately 200 L were sampled, with a pH of 5.2 and a turbidity of 12.04 NTU. The research employs a combined treatment process involving coagulants, specifically ferric sulfate and polyaluminum chloride, followed by filtration through activated carbon. Additionally, a low-cost monitoring system using an Arduino-based turbidimeter and colorimeter is proposed to measure water quality before and after treatment. The system incorporates a TS-300B turbidity sensor and a custom-built Arduino colorimeter utilizing the BPW34 sensor. Experimental results show a maximum color removal efficiency of 95.71% and a turbidity reduction of 70.43% under optimal conditions. The activated carbon used had the following properties: an iodine number of 902.85 mg/g, 10.73 mmol of acidic groups, and a point of zero charge (PZC) of 9.3. The turbidimeter and colorimeter cost $40.46 and $58.15, respectively. Validation parameters for the instruments were as follows: Pearson correlation coefficient of 99.98%, MAE of 2.46, RMSE of 3.80, and MAPE of 2.18% for the turbidimeter, and Pearson correlation coefficient of 99.73%, MAE of 0.07, RMSE of 0.08, and MAPE of 9.44 % for the colorimeter. This innovative solution demonstrates the feasibility of using low-cost technology for effective water treatment, contributing to sustainable agricultural practices by improving irrigation water quality and promoting better crop health and environmental protection. • Implementation of an automated monitoring system with Arduino to control the removal of turbidity and color in irrigation water. • Use of coagulants (ferric sulfate and polyvinyl chloride) and activated carbon to improve the water quality of the Moche River. • The Arduino system measures and validates turbidity and color in real time using sensors calibrated with commercial equipment. • Maximum color removal of 95.71% and turbidity of 70.43% was achieved at optimal recirculation times. • The system is affordable, economical and efficient for implementation in large-scale water treatment studies.

Case Studies in Chemical and Environmental EngineeringVol. 10
National University of Trujillo (PE), Universidad Nacional de San Martín (PE), Universidad Nacional José Faustino Sánchez Carrión (PE), Universidad Tecnológica del Perú (PE)
Clean water and sanitation
Openalex Percentile: Top 38%
Water Quality Monitoring Technologies
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.