Bone ingrowth in randomly distributed porous interbody cage during lumbar spinal fusion

Porous interbody cages are often used in spinal fusion surgery since they allow bone ingrowth which facilitates long-term stability. However, the extent of bone ingrowth in and around porous interbody cages has scarcely been investigated. Moreover, tissue differentiation might not be similar around the superior and inferior cage-bone interfaces. Using mechanobiology-based numerical framework and physiologic loading conditions, the study investigates the spatial distribution of evolutionary bone ingrowth within randomly distributed porous interbody cages, having varied porosities. Finite Element (FE) microscale models, corresponding to cage porosities of 60 %, 72 %, and 83 %, were developed for the superior and inferior interfacial regions of the cage, along with the macroscale model of the implanted lumbar spine. The implant-bone relative displacements of different porosity models were mapped from macroscale to microscale model. Bone formation of 10-40 % was predicted across the porous cage models, resulting in an average Young's modulus ranging between 765 MPa and 915 MPa. Maximum bone ingrowth of ∼34 % was observed for the 83 % porous cage, which was subject to low implant-bone relative displacements (maximum 50μm). New bone formation was found to be greater at the superior interface (∼34 %) as compared to the inferior interface (∼30 %) for P83 model. Relatively greater volume of fibrous tissue was formed at the implant-bone interface for the cage with 60 % and 72 % porosities, which might lead to cage migration and eventual failure of the implant. Hence, the interbody cage with 83 % porosity appears to be most favorable for bone ingrowth, provided sufficient mechanical strength is offered.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2024-10-18
DOI
https://doi.org/10.1016/j.medengphy.2024.104248
Citations
2
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bone ingrowth in randomly distributed porous interbody cage during lumbar spinal fusion

Santanu Dhara, Sanjay Gupta, Rahul Gautam Talukdar
2 citations
Medical Engineering & Physics
Orthopaedic implants and arthroplasty
1.15
article

Bone ingrowth in randomly distributed porous interbody cage during lumbar spinal fusion

Santanu Dhara, Sanjay Gupta, Rahul Gautam Talukdar
article en
2 citations

Abstract

Porous interbody cages are often used in spinal fusion surgery since they allow bone ingrowth which facilitates long-term stability. However, the extent of bone ingrowth in and around porous interbody cages has scarcely been investigated. Moreover, tissue differentiation might not be similar around the superior and inferior cage-bone interfaces. Using mechanobiology-based numerical framework and physiologic loading conditions, the study investigates the spatial distribution of evolutionary bone ingrowth within randomly distributed porous interbody cages, having varied porosities. Finite Element (FE) microscale models, corresponding to cage porosities of 60 %, 72 %, and 83 %, were developed for the superior and inferior interfacial regions of the cage, along with the macroscale model of the implanted lumbar spine. The implant-bone relative displacements of different porosity models were mapped from macroscale to microscale model. Bone formation of 10-40 % was predicted across the porous cage models, resulting in an average Young's modulus ranging between 765 MPa and 915 MPa. Maximum bone ingrowth of ∼34 % was observed for the 83 % porous cage, which was subject to low implant-bone relative displacements (maximum 50μm). New bone formation was found to be greater at the superior interface (∼34 %) as compared to the inferior interface (∼30 %) for P83 model. Relatively greater volume of fibrous tissue was formed at the implant-bone interface for the cage with 60 % and 72 % porosities, which might lead to cage migration and eventual failure of the implant. Hence, the interbody cage with 83 % porosity appears to be most favorable for bone ingrowth, provided sufficient mechanical strength is offered.

Medical Engineering & PhysicsVol. 133(1)
Indian Institute of Technology Kharagpur (IN)
Department of Science and Technology, Ministry of Science and Technology, India, Science and Engineering Research Board
Zero hunger
Openalex Percentile: Top 20%
Orthopaedic implants and arthroplasty
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.