Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom

<i>Objective.</i>This study aimed to optimise Cone Beam Computed Tomography (CBCT) protocols for head and neck (H&N) radiotherapy treatments using a 3D printed anthropomorphic phantom. It focused on precise patient positioning in conventional treatment and adaptive radiotherapy (ART).<i>Approach.</i>Ten CBCT protocols were evaluated with the 3D-printed H&N anthropomorphic phantom, including one baseline protocol currently used at our centre and nine new protocols. Adjustments were made to milliamperage and exposure time to explore their impact on radiation dose and image quality. Additionally, the effect on image quality of varying the scatter correction parameter for each of the protocols was assessed. Each protocol was compared against a reference CT scan. Usability was assessed by three Clinical Scientists using a Likert scale, and statistical validation was performed on the findings.<i>Main results</i>. The work revealed variability in the effectiveness of protocols. Protocols optimised for lower radiation exposure maintained sufficient image quality for patient setup in a conventional radiotherapy pathway, suggesting the potential for reducing patient radiation dose by over 50% without compromising efficacy. Optimising ART protocols involves balancing accuracy across brain, bone, and soft tissue, as no single protocol or scatter correction parameter achieves optimal results for all simultaneously.<i>Significance.</i>This study underscores the importance of optimising CBCT protocols in H&N radiotherapy. Our findings highlight the potential to maintain the usability of CBCT for bony registration in patient setup while significantly reducing the radiation dose, emphasizing the significance of optimising imaging protocols for the task in hand (registering to soft tissue or bone) and aligning with the as low as reasonably achievable principle. More studies are needed to assess these protocols for ART, including CBCT dose measurements and CT comparisons. Furthermore, the novel 3D printed anthropomorphic phantom demonstrated to be a useful tool when optimising CBCT protocols.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-18
DOI
https://doi.org/10.1088/1361-6560/ad88d2
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom

Bashar Al‐Qaisieh, M. Naisbit, D. J. Bird, Christopher O’Hara et al.
2 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
1.22
article

Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom

Bashar Al‐Qaisieh, M. Naisbit, D. J. Bird, Christopher O’Hara, Irvin Teh, Emily Johnstone, R. Speight, David Broadbent, Meshal Alzahrani, Jack P.C. Baldwin
article en
2 citations

Abstract

<i>Objective.</i>This study aimed to optimise Cone Beam Computed Tomography (CBCT) protocols for head and neck (H&N) radiotherapy treatments using a 3D printed anthropomorphic phantom. It focused on precise patient positioning in conventional treatment and adaptive radiotherapy (ART).<i>Approach.</i>Ten CBCT protocols were evaluated with the 3D-printed H&N anthropomorphic phantom, including one baseline protocol currently used at our centre and nine new protocols. Adjustments were made to milliamperage and exposure time to explore their impact on radiation dose and image quality. Additionally, the effect on image quality of varying the scatter correction parameter for each of the protocols was assessed. Each protocol was compared against a reference CT scan. Usability was assessed by three Clinical Scientists using a Likert scale, and statistical validation was performed on the findings.<i>Main results</i>. The work revealed variability in the effectiveness of protocols. Protocols optimised for lower radiation exposure maintained sufficient image quality for patient setup in a conventional radiotherapy pathway, suggesting the potential for reducing patient radiation dose by over 50% without compromising efficacy. Optimising ART protocols involves balancing accuracy across brain, bone, and soft tissue, as no single protocol or scatter correction parameter achieves optimal results for all simultaneously.<i>Significance.</i>This study underscores the importance of optimising CBCT protocols in H&N radiotherapy. Our findings highlight the potential to maintain the usability of CBCT for bony registration in patient setup while significantly reducing the radiation dose, emphasizing the significance of optimising imaging protocols for the task in hand (registering to soft tissue or bone) and aligning with the as low as reasonably achievable principle. More studies are needed to assess these protocols for ART, including CBCT dose measurements and CT comparisons. Furthermore, the novel 3D printed anthropomorphic phantom demonstrated to be a useful tool when optimising CBCT protocols.

Physics in Medicine and BiologyVol. 69(21)
Leeds General Infirmary (GB), University of Leeds (GB), King Abdulaziz University (SA), Leeds Teaching Hospitals NHS Trust (GB), St James's University Hospital (GB), The Christie Hospital (GB), The Christie NHS Foundation Trust (GB)
Good health and well-being
Openalex Percentile: Top 20%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.