IPEM topical report: the first UK survey of cone beam CT dose indices in radiotherapy verification imaging for adult patients

Cone beam CT is integral to most modern radiotherapy treatments. The application of daily and repeat CBCT imaging can lead to high imaging doses over a large volume of tissue that extends beyond the treatment site. Hence, it is important to ensure exposures are optimised to keep doses as low as reasonably achievable, whilst ensuring images are suitable for the clinical task. This IPEM topical report presents the results of the first UK survey of dose indices in radiotherapy CBCT. Dose measurements, as defined by the cone beam dose index (CBDI<sub>w</sub>), were collected along with protocol information for seven treatment sites. Where a range of optimised protocols were available in a centre, a sample of patient data demonstrating the variation in protocol use were requested. Protocol CBDI<sub>w</sub>values were determined from the average dosimetry data for each type of linear accelerator, and median CBDI<sub>w</sub>and scan length were calculated for each treatment site at each centre. Median CBDI<sub>w</sub>values were compared and summary statistics derived that enable the setting of national dose reference levels (DRLs). A total of 63 UK radiotherapy centres contributed data. The proposed CBDI<sub>w</sub>DRLs are; prostate 20.6 mGy, gynaecological 20.8 mGy, breast 5.0 mGy, 3D-lung 6.0 mGy, 4D-lung 11.8 mGy, brain 3.5 mGy and head/neck 4.2 mGy. However, large differences between models of imaging system were noted. Where centres had pro-active optimisation strategies in place, such as sized based protocols with selection criteria, dose reductions on the 'average' patient were possible compared with vendor defaults. Optimisation of scan length was noted in some clinical sites, with Elekta users tending to fit different collimators for prostate imaging (relatively short) compared with gynaecological treatments (longest). This contrasts with most Varian users who apply the default scan length in most cases.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-18
DOI
https://doi.org/10.1088/1361-6560/ad88d1
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IPEM topical report: the first UK survey of cone beam CT dose indices in radiotherapy verification imaging for adult patients

Matthew Williams, Tim J Wood, Rosaleen Plaistow, Úna Findlay et al.
2 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
1.22
article

IPEM topical report: the first UK survey of cone beam CT dose indices in radiotherapy verification imaging for adult patients

Matthew Williams, Tim J Wood, Rosaleen Plaistow, Úna Findlay, R. Bruce Lindsay, Sue Edyvean, Anne Davis, James J. Earley
article en
2 citations

Abstract

Cone beam CT is integral to most modern radiotherapy treatments. The application of daily and repeat CBCT imaging can lead to high imaging doses over a large volume of tissue that extends beyond the treatment site. Hence, it is important to ensure exposures are optimised to keep doses as low as reasonably achievable, whilst ensuring images are suitable for the clinical task. This IPEM topical report presents the results of the first UK survey of dose indices in radiotherapy CBCT. Dose measurements, as defined by the cone beam dose index (CBDI<sub>w</sub>), were collected along with protocol information for seven treatment sites. Where a range of optimised protocols were available in a centre, a sample of patient data demonstrating the variation in protocol use were requested. Protocol CBDI<sub>w</sub>values were determined from the average dosimetry data for each type of linear accelerator, and median CBDI<sub>w</sub>and scan length were calculated for each treatment site at each centre. Median CBDI<sub>w</sub>values were compared and summary statistics derived that enable the setting of national dose reference levels (DRLs). A total of 63 UK radiotherapy centres contributed data. The proposed CBDI<sub>w</sub>DRLs are; prostate 20.6 mGy, gynaecological 20.8 mGy, breast 5.0 mGy, 3D-lung 6.0 mGy, 4D-lung 11.8 mGy, brain 3.5 mGy and head/neck 4.2 mGy. However, large differences between models of imaging system were noted. Where centres had pro-active optimisation strategies in place, such as sized based protocols with selection criteria, dose reductions on the 'average' patient were possible compared with vendor defaults. Optimisation of scan length was noted in some clinical sites, with Elekta users tending to fit different collimators for prostate imaging (relatively short) compared with gynaecological treatments (longest). This contrasts with most Varian users who apply the default scan length in most cases.

Physics in Medicine and BiologyVol. 69(22)
University of Leeds (GB), Velindre NHS Trust (GB), Castle Hill Hospital (GB), Cambridge University Hospitals NHS Foundation Trust (GB), Public Health England (GB), Portsmouth Hospitals NHS Trust (GB), Royal Surrey NHS Foundation Trust (GB), Institute of Radiotherapy and Nuclear Medicine (PK), Hull York Medical School (GB)
Good health and well-being
Openalex Percentile: Top 20%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.