Verification of mean dose in a tumor using 3D-printed tumor-model scintillators in anthropomorphic phantoms and a spherical phantom

To enhance treatment outcomes of radiotherapy, accurate verification of dosimetric parameters such as the mean, minimum, and maximum doses is essential. This study aimed to measure the mean absorbed dose in a tumor-shaped target and compare the results with the calculated value of the treatment planning system. Tumor model scintillators (TMSs) mimicking brain tumors were fabricated with a commercial 3D printer based on stereolithography files of tumors. The TMSs were irradiated following treatment plans made with the Leksell Gamma Plan® (Elekta AB, Stockholm, Sweden), and the mean dose in each TMS was measured three times and compared with the calculated value. Eleven TMSs were set at the center of a spherical solid water phantom. Two additional TMSs were fabricated according to images of vestibular schwannomas and were set at the tumor location in head model phantoms following each patient's head shape. The mean relative differences between the measured and calculated mean doses were less than one percent. This method provides an independent parameter for evaluating the accuracy of the treatment planning system.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2024-10-18
DOI
https://doi.org/10.1016/j.net.2024.10.024
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification of mean dose in a tumor using 3D-printed tumor-model scintillators in anthropomorphic phantoms and a spherical phantom

Hyun‐Tai Chung, Kyo-Tae Kim, Yona Choi, Young Chan Seo et al.
1 citations
Nuclear Engineering and Technology
Advanced Radiotherapy Techniques
0.61
article

Verification of mean dose in a tumor using 3D-printed tumor-model scintillators in anthropomorphic phantoms and a spherical phantom

Hyun‐Tai Chung, Kyo-Tae Kim, Yona Choi, Young Chan Seo, Jungbae Bahng, Tae Hoon Kim, Yong Kyun Kim, Hye Jeong Yang
article en
1 citations

Abstract

To enhance treatment outcomes of radiotherapy, accurate verification of dosimetric parameters such as the mean, minimum, and maximum doses is essential. This study aimed to measure the mean absorbed dose in a tumor-shaped target and compare the results with the calculated value of the treatment planning system. Tumor model scintillators (TMSs) mimicking brain tumors were fabricated with a commercial 3D printer based on stereolithography files of tumors. The TMSs were irradiated following treatment plans made with the Leksell Gamma Plan® (Elekta AB, Stockholm, Sweden), and the mean dose in each TMS was measured three times and compared with the calculated value. Eleven TMSs were set at the center of a spherical solid water phantom. Two additional TMSs were fabricated according to images of vestibular schwannomas and were set at the tumor location in head model phantoms following each patient's head shape. The mean relative differences between the measured and calculated mean doses were less than one percent. This method provides an independent parameter for evaluating the accuracy of the treatment planning system.

Nuclear Engineering and TechnologyVol. 57(3)
Korea Development Institute (KR), Seoul National University (KR), General Electric (Spain) (ES), Seoul National University Hospital (KR), Korea Institute of Radiological and Medical Sciences (KR), National Cancer Center (US), Kangwon National University Hospital (KR), National Cancer Center (KR), Hanyang University (KR)
Openalex Percentile: Top 30%
Advanced Radiotherapy Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.