Environmentally friendly chemical–magnetorheological finishing method for Ti–6Al–4V biological material based on Fe3O4@SiO2, oxaloacetate acid and H2O2

Titanium alloy is extensively utilised in various advanced equipment across multiple industries, especially in biological implantable devices. The surface machining of such devices is required to provide a finished surface with high precision and gloss. This study presents an established ecofriendly slurry for a hybrid polishing process utilising a highly efficient chemical and magnetorheological fluid (C-MRF) to obtain ultraprecise surface quality. This slurry incorporated Fe 3 O 4 @SiO 2 abrasive particles, oxaloacetate acid (C 4 H 6 O 5 ), deionised water and hydrogen peroxide (H 2 O 2 ) as an oxidiser. Ti–6Al–4V workpieces polished with C-MRF based on Fe 3 O 4 @SiO 2 abrasives and polishing performance were used to investigate the influence of the oxidising agent H 2 O 2 and oxaloacetate acid (monitored with a pH indicator) on the surface finish of Ti–6Al–4V biomaterial. In contrast to the traditional mechanical and chemical polishing methods for titanium alloys that often include strong bases and acids along with chemicals that endanger the environment and humans, the proposed polishing process based on the newly developed ecofriendly magnetic composite leveraged the advantages of magnetorheological fluid with chemical reactions to create an ultra smooth surface. Experiments were performed to investigate the influence of different polishing durations and factors on the quality of polished surfaces, thereby optimising technological parameters, reducing time and improving surface quality. Various technological parameters were evaluated through single-factor and orthogonal experiments to assess their distinct effects on surface quality and material removal capability. This work proposed an environmentally friendly C-MRF method for finishing Ti–6Al–4V biomaterial with high efficiency and industrial applicability.

Authors

Institutions

Publication Details

Journal
International Journal of Lightweight Materials and Manufacture
Published
2024-10-18
DOI
https://doi.org/10.1016/j.ijlmm.2024.10.004
Citations
6
Primary Topic
Advanced Surface Polishing Techniques
Type
article
Field-Weighted Citation Impact
1.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmentally friendly chemical–magnetorheological finishing method for Ti–6Al–4V biological material based on Fe3O4@SiO2, oxaloacetate acid and H2O2

Trinh Duy Nguyen, Le Anh Duc, Vu Minh Yen
6 citations
International Journal of Lightweight Materials and Manufacture
Advanced Surface Polishing Techniques
1.11
article

Environmentally friendly chemical–magnetorheological finishing method for Ti–6Al–4V biological material based on Fe3O4@SiO2, oxaloacetate acid and H2O2

Trinh Duy Nguyen, Le Anh Duc, Vu Minh Yen
article en
6 citations

Abstract

Titanium alloy is extensively utilised in various advanced equipment across multiple industries, especially in biological implantable devices. The surface machining of such devices is required to provide a finished surface with high precision and gloss. This study presents an established ecofriendly slurry for a hybrid polishing process utilising a highly efficient chemical and magnetorheological fluid (C-MRF) to obtain ultraprecise surface quality. This slurry incorporated Fe 3 O 4 @SiO 2 abrasive particles, oxaloacetate acid (C 4 H 6 O 5 ), deionised water and hydrogen peroxide (H 2 O 2 ) as an oxidiser. Ti–6Al–4V workpieces polished with C-MRF based on Fe 3 O 4 @SiO 2 abrasives and polishing performance were used to investigate the influence of the oxidising agent H 2 O 2 and oxaloacetate acid (monitored with a pH indicator) on the surface finish of Ti–6Al–4V biomaterial. In contrast to the traditional mechanical and chemical polishing methods for titanium alloys that often include strong bases and acids along with chemicals that endanger the environment and humans, the proposed polishing process based on the newly developed ecofriendly magnetic composite leveraged the advantages of magnetorheological fluid with chemical reactions to create an ultra smooth surface. Experiments were performed to investigate the influence of different polishing durations and factors on the quality of polished surfaces, thereby optimising technological parameters, reducing time and improving surface quality. Various technological parameters were evaluated through single-factor and orthogonal experiments to assess their distinct effects on surface quality and material removal capability. This work proposed an environmentally friendly C-MRF method for finishing Ti–6Al–4V biomaterial with high efficiency and industrial applicability.

International Journal of Lightweight Materials and ManufactureVol. 8(2)
Hanoi University of Industry (VN)
Responsible consumption and production
Openalex Percentile: Top 24%
Advanced Surface Polishing Techniques
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Environmentally friendly chemical–magnetorheological finishing method for Ti–6Al–4V biological material based on Fe3O4@SiO2, oxaloacetate acid and H2O2 — Trinh Duy Nguyen, Le Anh Duc, et al. · International Journal of Lightweight Materials and Manufacture (2024) | TGRS Research Map | TGRS