Quantitative Comparison of Color-Coded Parametric Imaging Technologies Based on Digital Subtraction and Digital Variance Angiography: A Retrospective Observational Study

The evaluation of hemodynamic conditions in critical limb-threatening ischemia (CLTI) patients is inevitable in endovascular interventions. In this study, the performance of color-coded digital subtraction angiography (ccDSA) and the recently developed color-coded digital variance angiography (ccDVA) was compared in the assessment of key time parameters in lower extremity interventions. The observational study included 19 CLTI patients who underwent peripheral vascular intervention at our institution in 2020. Pre- and post-dilatational images were retrospectively processed and analyzed by a commercially available ccDSA software (Kinepict Medical Imaging Tool 6.0.3; Kinepict Health Ltd., Budapest, Hungary) and by the recently developed ccDVA technology. Two protocols were applied using both a 4 and 7.5 frames per second acquisition rate. Time-to-peak (TTP) parameters were determined in four pre- and poststenotic regions of interest (ROI), and ccDVA values were compared to ccDSA read-outs. The ccDVA technology provided practically the same TTP values as ccDSA (r = 0.99, R<sup>2</sup> = 0.98, <i>p</i> < 0.0001). The correlation was extremely high independently of the applied protocol or the position of ROI; the r value was 0.99 (R<sup>2</sup> = 0.98, <i>p</i> < 0.0001) in all groups. A similar correlation was observed in the change in passage time (r = 0.98, R<sup>2</sup> = 0.96, <i>p</i> < 0.0001). The color-coded DVA technology can reproduce the same hemodynamic data as a commercially available DSA-based software; therefore, it has the potential to be an alternative decision-supporting tool in catheter labs.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2024-10-18
DOI
https://doi.org/10.3390/jimaging10100260
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Comparison of Color-Coded Parametric Imaging Technologies Based on Digital Subtraction and Digital Variance Angiography: A Retrospective Observational Study

Krisztián Szigeti, Marcell Gyánó, Péter Sótonyi, Szabolcs Osváth et al.
Journal of Imaging
Peripheral Artery Disease Management
article

Quantitative Comparison of Color-Coded Parametric Imaging Technologies Based on Digital Subtraction and Digital Variance Angiography: A Retrospective Observational Study

Krisztián Szigeti, Marcell Gyánó, Péter Sótonyi, Szabolcs Osváth, J. Kiss, Balázs Nemes, István Góg
article en

Abstract

The evaluation of hemodynamic conditions in critical limb-threatening ischemia (CLTI) patients is inevitable in endovascular interventions. In this study, the performance of color-coded digital subtraction angiography (ccDSA) and the recently developed color-coded digital variance angiography (ccDVA) was compared in the assessment of key time parameters in lower extremity interventions. The observational study included 19 CLTI patients who underwent peripheral vascular intervention at our institution in 2020. Pre- and post-dilatational images were retrospectively processed and analyzed by a commercially available ccDSA software (Kinepict Medical Imaging Tool 6.0.3; Kinepict Health Ltd., Budapest, Hungary) and by the recently developed ccDVA technology. Two protocols were applied using both a 4 and 7.5 frames per second acquisition rate. Time-to-peak (TTP) parameters were determined in four pre- and poststenotic regions of interest (ROI), and ccDVA values were compared to ccDSA read-outs. The ccDVA technology provided practically the same TTP values as ccDSA (r = 0.99, R<sup>2</sup> = 0.98, <i>p</i> < 0.0001). The correlation was extremely high independently of the applied protocol or the position of ROI; the r value was 0.99 (R<sup>2</sup> = 0.98, <i>p</i> < 0.0001) in all groups. A similar correlation was observed in the change in passage time (r = 0.98, R<sup>2</sup> = 0.96, <i>p</i> < 0.0001). The color-coded DVA technology can reproduce the same hemodynamic data as a commercially available DSA-based software; therefore, it has the potential to be an alternative decision-supporting tool in catheter labs.

Journal of ImagingVol. 10(10)
Semmelweis University (HU)
Nemzeti Kutatási és Technológiai Hivatal
Openalex Percentile: Top 66%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.