Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses

Abstract Objective To evaluate the visual performance and patient satisfaction of three intraocular lenses (IOLs): the newly-designed monofocal-plus Tecnis Eyhance, multifocal Tecnis Synergy, and monofocal Sensar (Johnson & Johnson Surgical Vision©, Inc. Santa Ana, CA, USA). Methods This prospective, comparative, interventional study enrolled patients undergoing cataract surgery with implantation of Eyhance, Sensar, or Synergy IOLs. Postoperative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were assessed at distance (6m), intermediate (70 cm), and near (40 cm) in LogMAR units. Contrast sensitivity (CS) was measured using the Pelli-Robson chart at distance and near vision. Subjective visual comfort was evaluated through a validated questionnaire. Results The study included 52 participants (52% females; 84 eyes): 40 eyes with Eyhance, 26 with Synergy, and 18 with Sensar. Ages ranged from 48 to 82 years (mean age 70.2 ± 7.59 years), with 59% female participants. There was no significant difference in distance UCVA among the IOL types (P > 0.8). Synergy showed superior intermediate and near UCVA compared to Eyhance and Sensar (P < 0.01). Eyhance and Sensar demonstrated better distance CS than Synergy (P ≤ 0.05) and better near CS (P < 0.05). Questionnaire responses showed no significant difference in overall visual comfort, but higher satisfaction with intermediate vision was reported for Synergy. Conclusions The Synergy lens is recommended for patients prioritizing intermediate and near vision. Eyhance did not show an objective advantage over Sensar for intermediate vision and contrast sensitivity (CS) but had a subjective advantage. Despite reduced CS, Synergy provided excellent distance UCVA, similar to Eyhance and Sensar.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-06
DOI
https://doi.org/10.3390/jcm15218651
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses

Hadas Ben‐Eli, Inbar Wunch, Arie Marcovitch, Riki Maroko et al.
1 links
Journal of Clinical Medicine
Intraocular Surgery and Lenses
article

Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses

Hadas Ben‐Eli, Inbar Wunch, Arie Marcovitch, Riki Maroko, Tamar Winnett, Deborah Berrih-Elkouby
article en

Abstract

Abstract Objective To evaluate the visual performance and patient satisfaction of three intraocular lenses (IOLs): the newly-designed monofocal-plus Tecnis Eyhance, multifocal Tecnis Synergy, and monofocal Sensar (Johnson & Johnson Surgical Vision©, Inc. Santa Ana, CA, USA). Methods This prospective, comparative, interventional study enrolled patients undergoing cataract surgery with implantation of Eyhance, Sensar, or Synergy IOLs. Postoperative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were assessed at distance (6m), intermediate (70 cm), and near (40 cm) in LogMAR units. Contrast sensitivity (CS) was measured using the Pelli-Robson chart at distance and near vision. Subjective visual comfort was evaluated through a validated questionnaire. Results The study included 52 participants (52% females; 84 eyes): 40 eyes with Eyhance, 26 with Synergy, and 18 with Sensar. Ages ranged from 48 to 82 years (mean age 70.2 ± 7.59 years), with 59% female participants. There was no significant difference in distance UCVA among the IOL types (P > 0.8). Synergy showed superior intermediate and near UCVA compared to Eyhance and Sensar (P < 0.01). Eyhance and Sensar demonstrated better distance CS than Synergy (P ≤ 0.05) and better near CS (P < 0.05). Questionnaire responses showed no significant difference in overall visual comfort, but higher satisfaction with intermediate vision was reported for Synergy. Conclusions The Synergy lens is recommended for patients prioritizing intermediate and near vision. Eyhance did not show an objective advantage over Sensar for intermediate vision and contrast sensitivity (CS) but had a subjective advantage. Despite reduced CS, Synergy provided excellent distance UCVA, similar to Eyhance and Sensar.

Journal of Clinical MedicineVol. 15(21)
Kaplan Medical Center (IL), Jerusalem Multidisciplinary College (IL)
Good health and well-being
Openalex Percentile: Top 100%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon