In large-format pouch cells for electric vehicles, the issues of elevated and non-uniform temperatures resulting from heat generation are intensified, necessitating the use of liquid cooling systems. The design factors of the liquid cooling system influence the maximum temperature and temperature differences in the module as well as the pumping power of the cooling system. Although it is known that these design factors interact, research on these interactions and their effects is currently lacking. In this study, the individual as well as interaction effects of design factors on the performance of the liquid cooling system for a large-format pouch cell module were investigated using design of experiment and analyzed through statistical methods. Electrochemical–thermal fluid coupled analysis was used to calculate the performance according to the design factors of the liquid cooling system. The wall and channel widths are factors that directly determine the coolant flow velocity and cooling plate heat capacity, and they exhibited major effects on all three responses. Moreover, the influence of each design factor tended to change in response to variations in the other design factors. Thus, the effects of each factor individually and of interactions between factors were quantitatively compared and evaluated for significance. The width of the walls was found to contribute the most to the maximum temperature (36.00%) and pumping power (57.56%), while the width of the channels contributed the most to the temperature difference (38.24%), indicating that they are the main influencing factors.

Authors

Institutions

Publication Details

Journal
Mathematics
Published
2024-10-17
DOI
https://doi.org/10.3390/math12203261
Citations
4
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical–Thermal Fluid Coupled Analysis and Statistical Analysis of Cooling System for Large Pouch Cells

Hamin Lee, Seokjun Park, Chang‐Wan Kim
4 citations
Mathematics
Adsorption and Cooling Systems
0.85
article

Electrochemical–Thermal Fluid Coupled Analysis and Statistical Analysis of Cooling System for Large Pouch Cells

Hamin Lee, Seokjun Park, Chang‐Wan Kim
article en
4 citations

Abstract

In large-format pouch cells for electric vehicles, the issues of elevated and non-uniform temperatures resulting from heat generation are intensified, necessitating the use of liquid cooling systems. The design factors of the liquid cooling system influence the maximum temperature and temperature differences in the module as well as the pumping power of the cooling system. Although it is known that these design factors interact, research on these interactions and their effects is currently lacking. In this study, the individual as well as interaction effects of design factors on the performance of the liquid cooling system for a large-format pouch cell module were investigated using design of experiment and analyzed through statistical methods. Electrochemical–thermal fluid coupled analysis was used to calculate the performance according to the design factors of the liquid cooling system. The wall and channel widths are factors that directly determine the coolant flow velocity and cooling plate heat capacity, and they exhibited major effects on all three responses. Moreover, the influence of each design factor tended to change in response to variations in the other design factors. Thus, the effects of each factor individually and of interactions between factors were quantitatively compared and evaluated for significance. The width of the walls was found to contribute the most to the maximum temperature (36.00%) and pumping power (57.56%), while the width of the channels contributed the most to the temperature difference (38.24%), indicating that they are the main influencing factors.

MathematicsVol. 12(20)
Konkuk University (KR)
Konkuk University
Affordable and clean energy
Openalex Percentile: Top 30%
Adsorption and Cooling Systems
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electrochemical–Thermal Fluid Coupled Analysis and Statistical Analysis of Cooling System for Large Pouch Cells — Hamin Lee, Seokjun Park, et al. · Mathematics (2024) | TGRS Research Map | TGRS