A Wireless Miniature Injectable Device With Memory-Assisted Backscatter for Multimodal Animal Physiological Monitoring

This paper introduces a wirelessly powered multimodal animal physiological monitoring application-specific integrated circuit (ASIC). Fabricated in the 180 nm process, the ASIC can be integrated into an injectable device to monitor subcutaneous body temperature, electrocardiography (ECG), and photoplethysmography (PPG). To minimize the device size, the ASIC employs a miniature receiver (Rx) coil for wireless power receiving and data communication through a single inductive link operating at 13.56 MHz. We propose a folded L-shape Rx coil with improved coupling to the transmitter (Tx) coil, even in the presence of misalignment, and enhanced quality factor. The ASIC functions alternatively between recording and sleeping modes, consuming 2.55 µW on average. For PPG measurements, a reflection-type PPG sensor illuminates an LED with tunable current pulses. A current-input analog frontend (AFE) amplifies the current of a photodiode (PD) with 30.8 pA<sub>RMS</sub> current input-referred noise (IRN). The ECG AFE captures ECG signals with a configurable gain of 45-80 dB. The temperature AFE achieves 0.02 °C inaccuracy within a sensing range between 27-47 °C. The AFE outputs are sequentially digitized by a 10-bit successive approximation register (SAR) analog-to-digital converter (ADC) with an effective number of bits (ENOB) of 8.79. To improve the reliability of data transmission, we propose a memory-assisted backscatter scheme that stores ADC data in an off-chip memory and transmits it when the coupling condition is stable. This scheme achieves a package loss rate (PLR) lower than 0.2% while allowing 24-hour data storage. The device's functionality has been evaluated by in vivo experiments.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Engineering
Published
2024-10-17
DOI
https://doi.org/10.1109/tbme.2024.3482983
Citations
3
Primary Topic
Energy Harvesting in Wireless Networks
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wireless Miniature Injectable Device With Memory-Assisted Backscatter for Multimodal Animal Physiological Monitoring

Alper Bozkurt, Linran Zhao, Parvez Ahmmed, Yaoyao Jia et al.
3 citations
IEEE Transactions on Biomedical Engineering
Energy Harvesting in Wireless Networks
0.63
article

A Wireless Miniature Injectable Device With Memory-Assisted Backscatter for Multimodal Animal Physiological Monitoring

Alper Bozkurt, Linran Zhao, Parvez Ahmmed, Yaoyao Jia, Raymond G Stephany, Yiming Han
article en
3 citations

Abstract

This paper introduces a wirelessly powered multimodal animal physiological monitoring application-specific integrated circuit (ASIC). Fabricated in the 180 nm process, the ASIC can be integrated into an injectable device to monitor subcutaneous body temperature, electrocardiography (ECG), and photoplethysmography (PPG). To minimize the device size, the ASIC employs a miniature receiver (Rx) coil for wireless power receiving and data communication through a single inductive link operating at 13.56 MHz. We propose a folded L-shape Rx coil with improved coupling to the transmitter (Tx) coil, even in the presence of misalignment, and enhanced quality factor. The ASIC functions alternatively between recording and sleeping modes, consuming 2.55 µW on average. For PPG measurements, a reflection-type PPG sensor illuminates an LED with tunable current pulses. A current-input analog frontend (AFE) amplifies the current of a photodiode (PD) with 30.8 pA<sub>RMS</sub> current input-referred noise (IRN). The ECG AFE captures ECG signals with a configurable gain of 45-80 dB. The temperature AFE achieves 0.02 °C inaccuracy within a sensing range between 27-47 °C. The AFE outputs are sequentially digitized by a 10-bit successive approximation register (SAR) analog-to-digital converter (ADC) with an effective number of bits (ENOB) of 8.79. To improve the reliability of data transmission, we propose a memory-assisted backscatter scheme that stores ADC data in an off-chip memory and transmits it when the coupling condition is stable. This scheme achieves a package loss rate (PLR) lower than 0.2% while allowing 24-hour data storage. The device's functionality has been evaluated by in vivo experiments.

IEEE Transactions on Biomedical EngineeringVol. 72(3)
North Carolina State University (US), The University of Texas at Austin (US)
Zero hunger
Openalex Percentile: Top 31%
Energy Harvesting in Wireless Networks
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.