Novel Vitrectomy Technique Using Ocular Ultrasound for Vitreous Floaters

Objective: Limited Vitrectomy (CV) has a high chance of recurrence of floater symptoms. We evaluated the effectiveness and safety of a novel technique of vitrectomy: limited vitrectomy and selective removal of anterior vitreous opacities using 20 Megahertz (MHz) ocular ultrasound for vitreous floaters. Methods: We included 175 eyes of 101 participants who underwent the phacoemulsification with multifocal intraocular lens insertion. Participants were divided into 3 groups: novel vitrectomy (SV), CV and control groups. They were followed up at postoperative 1, 3 and 6 months. Visual Acuity (VA), Spherical Equivalent (SE), Intraocular Pressure (IOP), Contrast Sensitivity Function (CSF) and Patient Satisfaction (PS) were compared between the SV and CV groups. PS and national eye institute-validated visual function questionnaire-39 (NEI VFQ-39) composite scores were assessed. Comparison was performed using the independent Student’s t-test and Fisher’s exact test. Results: Best corrected VA was not significantly different in both groups. SE was significantly better in the SV group than in the CV group at 6 months postoperatively. There was no significant difference in IOP between both groups at 3 and 6 months postoperatively. The SV group had significantly better CSF than the CV group. The PS was higher in the SV group than in the CV group at 3 and 6 months postoperatively, based on the NEI VFQ-39 composite scores. There were no complications in the SV group. Endophthalmitis (n=1) and retinal detachment (n=1) occurred in the CV group. Conclusion: The novel 25-gauge CV combined with selectively peripheral and anterior vitrectomy using 20 MHz ocular ultrasound is a more effective and safer procedure compared with simple CV.

Authors

Publication Details

Journal
Journal of Ophthalmology and Advance Research
Published
2024-10-18
DOI
https://doi.org/10.46889/joar.2024.5304
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Vitrectomy Technique Using Ocular Ultrasound for Vitreous Floaters

Hyung‐Ju Park
Journal of Ophthalmology and Advance Research
Retinal and Macular Surgery
article

Novel Vitrectomy Technique Using Ocular Ultrasound for Vitreous Floaters

Hyung‐Ju Park
article en

Abstract

Objective: Limited Vitrectomy (CV) has a high chance of recurrence of floater symptoms. We evaluated the effectiveness and safety of a novel technique of vitrectomy: limited vitrectomy and selective removal of anterior vitreous opacities using 20 Megahertz (MHz) ocular ultrasound for vitreous floaters. Methods: We included 175 eyes of 101 participants who underwent the phacoemulsification with multifocal intraocular lens insertion. Participants were divided into 3 groups: novel vitrectomy (SV), CV and control groups. They were followed up at postoperative 1, 3 and 6 months. Visual Acuity (VA), Spherical Equivalent (SE), Intraocular Pressure (IOP), Contrast Sensitivity Function (CSF) and Patient Satisfaction (PS) were compared between the SV and CV groups. PS and national eye institute-validated visual function questionnaire-39 (NEI VFQ-39) composite scores were assessed. Comparison was performed using the independent Student’s t-test and Fisher’s exact test. Results: Best corrected VA was not significantly different in both groups. SE was significantly better in the SV group than in the CV group at 6 months postoperatively. There was no significant difference in IOP between both groups at 3 and 6 months postoperatively. The SV group had significantly better CSF than the CV group. The PS was higher in the SV group than in the CV group at 3 and 6 months postoperatively, based on the NEI VFQ-39 composite scores. There were no complications in the SV group. Endophthalmitis (n=1) and retinal detachment (n=1) occurred in the CV group. Conclusion: The novel 25-gauge CV combined with selectively peripheral and anterior vitrectomy using 20 MHz ocular ultrasound is a more effective and safer procedure compared with simple CV.

Journal of Ophthalmology and Advance Research
Openalex Percentile: Top 70%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.