Assessment of bioaerosols, PM<sub>2.5</sub>, and PM<sub>10</sub> in liver transplantation operating rooms in Tehran, Iran: Implications for air quality

Background: Research on the relationship between bioaerosols and particulate matter (PM) concentrations is necessary, especially in hospitals where airborne bioaerosols can facilitate disease transmission. This study aimed to investigate the relationship between PM (PM2.5 and PM10) and bioaerosols, as well as the factors influencing them (temperature and humidity), in the air of liver transplant operating rooms (LTOR) at Imam Khomeini Hospital in Tehran. Methods: Bioaerosol samples (32 samples) were collected using the passive sampling method, employing open-door plates containing culture medium, during June and July of 2019. PM samples were obtained concurrently with bioaerosol samples using the GM8803 air quality detector, during four one-hour periods. Simple linear regression analysis was performed to determine the relationship between bioaerosol and PM concentrations. Results: It was revealed that the average concentrations of PM2.5 and PM10 were 17.8 (SD=2.2) and 27.0 (SD=2.6) µg/m3 , respectively. Additionally, the average concentrations of bacterial and fungal bioaerosols were 2132 (SD=837) and 550 (SD=189.4) CFU/m2 .h, respectively. Linear regression analysis demonstrated a strong correlation between bacterial bioaerosols and PM concentrations, whereas the relationship with fungal bioaerosols was relatively weaker. Conclusion: The findings of this study indicate that the indoor air in LTOR exhibits a higher level of microbial contamination than the recommended guidelines for high-risk environments. To improve the air quality in LTOR, it is recommended to implement periodic microbial monitoring, ensure the proper functioning of ventilation systems, and pay attention to their maintenance and operation.

Authors

Institutions

Publication Details

Journal
Environmental Health Engineering and Management
Published
2024-09-08
DOI
https://doi.org/10.34172/ehem.2024.30
Citations
2
Primary Topic
Climate Change and Health Impacts
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of bioaerosols, PM2.5, and PM10 in liver transplantation operating rooms in Tehran, Iran: Implications for air quality

Kazem Naddafi, Majid Nozari, Saba Fouladvand, Mahmood Alimohammadi et al.
2 citations
Environmental Health Engineering and Management
Climate Change and Health Impacts
0.63
article

Assessment of bioaerosols, PM2.5, and PM10 in liver transplantation operating rooms in Tehran, Iran: Implications for air quality

Kazem Naddafi, Majid Nozari, Saba Fouladvand, Mahmood Alimohammadi, Mohammad Sadegh Hassanvand, Mohammad Reza Pourmand, Meraj Khalui
article en
2 citations

Abstract

Background: Research on the relationship between bioaerosols and particulate matter (PM) concentrations is necessary, especially in hospitals where airborne bioaerosols can facilitate disease transmission. This study aimed to investigate the relationship between PM (PM2.5 and PM10) and bioaerosols, as well as the factors influencing them (temperature and humidity), in the air of liver transplant operating rooms (LTOR) at Imam Khomeini Hospital in Tehran. Methods: Bioaerosol samples (32 samples) were collected using the passive sampling method, employing open-door plates containing culture medium, during June and July of 2019. PM samples were obtained concurrently with bioaerosol samples using the GM8803 air quality detector, during four one-hour periods. Simple linear regression analysis was performed to determine the relationship between bioaerosol and PM concentrations. Results: It was revealed that the average concentrations of PM2.5 and PM10 were 17.8 (SD=2.2) and 27.0 (SD=2.6) µg/m3 , respectively. Additionally, the average concentrations of bacterial and fungal bioaerosols were 2132 (SD=837) and 550 (SD=189.4) CFU/m2 .h, respectively. Linear regression analysis demonstrated a strong correlation between bacterial bioaerosols and PM concentrations, whereas the relationship with fungal bioaerosols was relatively weaker. Conclusion: The findings of this study indicate that the indoor air in LTOR exhibits a higher level of microbial contamination than the recommended guidelines for high-risk environments. To improve the air quality in LTOR, it is recommended to implement periodic microbial monitoring, ensure the proper functioning of ventilation systems, and pay attention to their maintenance and operation.

Environmental Health Engineering and ManagementVol. 11(3)
Biotechnology Research Center (IR), Bam University of Medical Sciences (IR), Zahedan University of Medical Sciences (IR), Tehran University of Medical Sciences (IR)
Openalex Percentile: Top 29%
Climate Change and Health Impacts
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.