The Panflute Technique: Novel 3D-Printed Patient Specific Instrumentation to Guide Curved Intra-Articular Osteotomies for Tibial Plateau Malunions

<b>Background/Objectives</b>: 3D patient-specific corrective osteotomies are optimized for use with oscillating saws, thereby rendering it incapable of executing curved osteotomies. The aim of this technical note is to introduce and evaluate the Panflute technique, which facilitates curved osteotomies with precise depth control for intra-articular corrective osteotomies in posttraumatic tibial plateau malunions. <b>Methods</b>: A 33-year-old male patient with an intra-articular malunion was treated one year after index surgery of a lateral split-depression tibial plateau fracture with the Panflute technique. The guide design allowed for multiple drill trajectories in a curved path, recreating the original fracture lines. Cylindrical drill tubes in the guide were tailored to match bone trajectory length. This resulted in a patient-specific Panflute-like design enabling precise depth control, safeguarding posterior neurovascular structures. Secondly, the recreated fragment was reduced with a reduction guide, applied to the plate in situ, to facilitate reposition using the plate as tool and reference. <b>Results</b>: The procedure went without technical drawbacks or surgical complications. Postoperative assessment showed that repositioning of the osteotomized articular fragment was performed accurately: pre- to postoperative translational corrections were 5.4 to 0.5 mm posterior displacement for AP deformity (<i>x</i>-axis); 2.9 to 1.0 mm lateral to medial reduction (<i>y</i>-axis); and 5.9 to 0.6 mm cranial-caudal correction (<i>z</i>-axis). Clinically, at 3 months, the fracture united, the patient regained full flexion, and valgus defect-laxity resolved. <b>Conclusions</b>: The presented Panflute-osteotomy guide allows for a pre-planned curved osteotomy. Additionally, for every drill trajectory, the depth could be controlled. The proposed method may expand our surgical armamentarium of patient-specific 3D techniques and solutions for complex intra-articular osteotomies.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-10-17
DOI
https://doi.org/10.3390/jcm13206175
Citations
2
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Panflute Technique: Novel 3D-Printed Patient Specific Instrumentation to Guide Curved Intra-Articular Osteotomies for Tibial Plateau Malunions

Peter A. J. Pijpker, Frank F. A. IJpma, Job Nicolaas Doornberg, Hugo C. van der Veen et al.
2 citations
Journal of Clinical Medicine
Bone fractures and treatments
0.77
article

The Panflute Technique: Novel 3D-Printed Patient Specific Instrumentation to Guide Curved Intra-Articular Osteotomies for Tibial Plateau Malunions

Peter A. J. Pijpker, Frank F. A. IJpma, Job Nicolaas Doornberg, Hugo C. van der Veen, Nick Assink, Cornelia W. Binnekamp
article en
2 citations

Abstract

<b>Background/Objectives</b>: 3D patient-specific corrective osteotomies are optimized for use with oscillating saws, thereby rendering it incapable of executing curved osteotomies. The aim of this technical note is to introduce and evaluate the Panflute technique, which facilitates curved osteotomies with precise depth control for intra-articular corrective osteotomies in posttraumatic tibial plateau malunions. <b>Methods</b>: A 33-year-old male patient with an intra-articular malunion was treated one year after index surgery of a lateral split-depression tibial plateau fracture with the Panflute technique. The guide design allowed for multiple drill trajectories in a curved path, recreating the original fracture lines. Cylindrical drill tubes in the guide were tailored to match bone trajectory length. This resulted in a patient-specific Panflute-like design enabling precise depth control, safeguarding posterior neurovascular structures. Secondly, the recreated fragment was reduced with a reduction guide, applied to the plate in situ, to facilitate reposition using the plate as tool and reference. <b>Results</b>: The procedure went without technical drawbacks or surgical complications. Postoperative assessment showed that repositioning of the osteotomized articular fragment was performed accurately: pre- to postoperative translational corrections were 5.4 to 0.5 mm posterior displacement for AP deformity (<i>x</i>-axis); 2.9 to 1.0 mm lateral to medial reduction (<i>y</i>-axis); and 5.9 to 0.6 mm cranial-caudal correction (<i>z</i>-axis). Clinically, at 3 months, the fracture united, the patient regained full flexion, and valgus defect-laxity resolved. <b>Conclusions</b>: The presented Panflute-osteotomy guide allows for a pre-planned curved osteotomy. Additionally, for every drill trajectory, the depth could be controlled. The proposed method may expand our surgical armamentarium of patient-specific 3D techniques and solutions for complex intra-articular osteotomies.

Journal of Clinical MedicineVol. 13(20)
University Medical Center Groningen (NL), University of Groningen (NL)
European Commission, Samenwerkingsverband Noord-Nederland
Openalex Percentile: Top 25%
Bone fractures and treatments
0.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.