Detection of Arc Faults in Transformer Windings via Transient Signal Analysis

In power transformers, lightning strikes, switching operations, and short circuit faults can deform the winding insulation, resulting in an electric arc between the windings. If the arc is not detected in its initial phase, it may lead to a solid short circuit and damage the transformer, potentially causing an explosion due to overheating and high pressure. In this study, winding arcs in the transformer are identified from the terminal current and voltage signals. A 3D magnetic model of a 15 MVA power transformer is constructed in Ansys@Maxwell, and the nonlinear arc model is simulated in Matlab@Simulink. The transient voltage and current signals related to the arcing conditions at five different points in the high-voltage side winding are obtained by running Ansys and Matlab simultaneously using ANSYS@Simplorer (Twin Builder). These signals are transformed into the frequency domain using Fast Fourier Transform (FFT). The arcs are detected from the transient-generated frequency components of the transformer voltage and current signals.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-10-14
DOI
https://doi.org/10.3390/app14209335
Citations
5
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Arc Faults in Transformer Windings via Transient Signal Analysis

Feyyaz Alpsalaz, Mehmet Salih Mamiş
5 citations
Applied Sciences
Power Transformer Diagnostics and Insulation
1.04
article

Detection of Arc Faults in Transformer Windings via Transient Signal Analysis

Feyyaz Alpsalaz, Mehmet Salih Mamiş
article en
5 citations

Abstract

In power transformers, lightning strikes, switching operations, and short circuit faults can deform the winding insulation, resulting in an electric arc between the windings. If the arc is not detected in its initial phase, it may lead to a solid short circuit and damage the transformer, potentially causing an explosion due to overheating and high pressure. In this study, winding arcs in the transformer are identified from the terminal current and voltage signals. A 3D magnetic model of a 15 MVA power transformer is constructed in Ansys@Maxwell, and the nonlinear arc model is simulated in Matlab@Simulink. The transient voltage and current signals related to the arcing conditions at five different points in the high-voltage side winding are obtained by running Ansys and Matlab simultaneously using ANSYS@Simplorer (Twin Builder). These signals are transformed into the frequency domain using Fast Fourier Transform (FFT). The arcs are detected from the transient-generated frequency components of the transformer voltage and current signals.

Applied SciencesVol. 14(20)
Inonu University (TR), Yozgat Bozok Üniversitesi (TR)
Affordable and clean energy
Openalex Percentile: Top 23%
Power Transformer Diagnostics and Insulation
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Arc Faults in Transformer Windings via Transient Signal Analysis — Feyyaz Alpsalaz, Mehmet Salih Mamiş · Applied Sciences (2024) | TGRS Research Map | TGRS