A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid

Developing antifouling biosensors capable of performing robustly in complex human body fluids is crucial for biomarker diagnosis and health monitoring. Herein, an antifouling and highly sensitive and stable biosensor was constructed through the self-assembly of the designed conjugates composed of a multifunctional peptide (MP) and PEGylated distearoylphosphatidylethanolamine (DSPE-PEG). The self-assembly capability of the DSPE-PEG-MP was demonstrated clearly through coarse-grained molecular dynamics simulation and transmission electron microscopy, and it can be effectively self-assembled onto the electrode surface modified with gold nanoparticles. The MP was designed to be antifouling and contained a peptide sequence that can specifically bind the target protein Annexin A1 (ANXA1), and the D-type amino acid composition of MP can enhance its resistance to enzymatic hydrolysis. The unique design of MP, in conjugation with the self-assembly capability of the PEGylated phospholipid DSPE-PEG, enabled the biosensor to exhibit excellent antifouling capability and stability in various complex human body fluids. The biosensor was capable of sensitively and selectively quantifying ANXA1 and achieved a limit of detection down to 0.12 pg mL<sup>-1</sup>. More importantly, the biosensor demonstrated satisfactory accuracy for ANXA1 detection in clinical serum samples, as verified by the enzyme linked immunosorbent assay (ELISA) kits. It is expected that various antifouling biosensors suitable for application in complex biological environments can be constructed by utilizing the strategy of designing similar DSPE-PEG-MP conjugates.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2024-10-17
DOI
https://doi.org/10.1021/acssensors.4c02425
Citations
10
Primary Topic
Lipid Membrane Structure and Behavior
Type
article
Field-Weighted Citation Impact
2.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid

Wenqing Wang, Xiliang Luo, Yang Li, Zhen Song et al.
10 citations
ACS Sensors
Lipid Membrane Structure and Behavior
2.34
article

A Nonfouling Electrochemical Biosensor for Protein Analysis in Complex Body Fluids Based on Multifunctional Peptide Conjugated with PEGlyated Phospholipid

Wenqing Wang, Xiliang Luo, Yang Li, Zhen Song, Rui Han, Baoping Zhu
article en
10 citations

Abstract

Developing antifouling biosensors capable of performing robustly in complex human body fluids is crucial for biomarker diagnosis and health monitoring. Herein, an antifouling and highly sensitive and stable biosensor was constructed through the self-assembly of the designed conjugates composed of a multifunctional peptide (MP) and PEGylated distearoylphosphatidylethanolamine (DSPE-PEG). The self-assembly capability of the DSPE-PEG-MP was demonstrated clearly through coarse-grained molecular dynamics simulation and transmission electron microscopy, and it can be effectively self-assembled onto the electrode surface modified with gold nanoparticles. The MP was designed to be antifouling and contained a peptide sequence that can specifically bind the target protein Annexin A1 (ANXA1), and the D-type amino acid composition of MP can enhance its resistance to enzymatic hydrolysis. The unique design of MP, in conjugation with the self-assembly capability of the PEGylated phospholipid DSPE-PEG, enabled the biosensor to exhibit excellent antifouling capability and stability in various complex human body fluids. The biosensor was capable of sensitively and selectively quantifying ANXA1 and achieved a limit of detection down to 0.12 pg mL<sup>-1</sup>. More importantly, the biosensor demonstrated satisfactory accuracy for ANXA1 detection in clinical serum samples, as verified by the enzyme linked immunosorbent assay (ELISA) kits. It is expected that various antifouling biosensors suitable for application in complex biological environments can be constructed by utilizing the strategy of designing similar DSPE-PEG-MP conjugates.

ACS SensorsVol. 9(10)
Qingdao University of Science and Technology (CN)
National Natural Science Foundation of China, Key Technology Research and Development Program of Shandong
Openalex Percentile: Top 11%
Lipid Membrane Structure and Behavior
2.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.