Highly Sensitive Electrochemiluminescence Biosensing Method for SARS-CoV-2 N Protein Incorporating the Micelle Probes of Quantum Dots and Dibenzoyl Peroxide Using the Screen-Printed Carbon Electrode Modified with a Carboxyl-Functionalized Graphene

Obtaining stable electrochemiluminescence (ECL) emissions from a hydrophobic luminophore in aqueous solutions and designing a method without the use of an exogenous coreactant are promising for ECL biosensing. Here, a highly sensitive signal-on ECL immunoassay for the SARS-CoV-2 N protein was developed using micelles as an ECL tag. The micelles were prepared by coencapsulating the luminophore hydrophobic CdSe/ZnS quantum dots and coreactant dibenzoyl peroxide within the hydrophobic core of micelles. The ECL probe was obtained by covalently bonding a SARS-CoV-2 N protein-binding aptamer onto the micelle surface. The construction of the immunosensor was initiated by the immobilization of the anti-SARS-CoV-2 N protein antibody onto the screen-printed carbon electrode (SPCE) with a -COOH-functionalized surface. The surface functionalization of SPCEs was achieved through paste-exfoliated graphene, which was modified with a -COOH group through supramolecular-covalent scaffolds on SPCE. Upon achieving sandwich complexes on the immunosensor, an efficient ECL signal response at -1.4 V versus Ag/AgCl was obtained in phosphate buffer solution. The ECL assay was used for the sensitive determination of SARS-CoV-2 N protein with the linear range from 0.01 to 50 ng mL<sup>-1</sup>, and the detection limit was 3.0 pg mL<sup>-1</sup>. The immunosensor showed good reproducibility and stability, and the ECL immunoassay was used to determine the SARS-CoV-2 N protein in serum samples. The proposed approach to obtain micelles is versatile for the preparation of stable ECL luminophores by using hydrophobic materials, and the strategy provides an alternative for ECL bioassays based on the coreactant route.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-17
DOI
https://doi.org/10.1021/acs.analchem.4c04024
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Electrochemiluminescence Biosensing Method for SARS-CoV-2 N Protein Incorporating the Micelle Probes of Quantum Dots and Dibenzoyl Peroxide Using the Screen-Printed Carbon Electrode Modified with a Carboxyl-Functionalized Graphene

Yulan Li, Peng Wu, Yingfeng Lei, Qiang Gao et al.
3 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
0.70
article

Highly Sensitive Electrochemiluminescence Biosensing Method for SARS-CoV-2 N Protein Incorporating the Micelle Probes of Quantum Dots and Dibenzoyl Peroxide Using the Screen-Printed Carbon Electrode Modified with a Carboxyl-Functionalized Graphene

Yulan Li, Peng Wu, Yingfeng Lei, Qiang Gao, Fanglin Zhang, Chengxiao Zhang, Honglan Qi, Liang Zhang, Linfeng Cheng, Guilan Zhang
article en
3 citations

Abstract

Obtaining stable electrochemiluminescence (ECL) emissions from a hydrophobic luminophore in aqueous solutions and designing a method without the use of an exogenous coreactant are promising for ECL biosensing. Here, a highly sensitive signal-on ECL immunoassay for the SARS-CoV-2 N protein was developed using micelles as an ECL tag. The micelles were prepared by coencapsulating the luminophore hydrophobic CdSe/ZnS quantum dots and coreactant dibenzoyl peroxide within the hydrophobic core of micelles. The ECL probe was obtained by covalently bonding a SARS-CoV-2 N protein-binding aptamer onto the micelle surface. The construction of the immunosensor was initiated by the immobilization of the anti-SARS-CoV-2 N protein antibody onto the screen-printed carbon electrode (SPCE) with a -COOH-functionalized surface. The surface functionalization of SPCEs was achieved through paste-exfoliated graphene, which was modified with a -COOH group through supramolecular-covalent scaffolds on SPCE. Upon achieving sandwich complexes on the immunosensor, an efficient ECL signal response at -1.4 V versus Ag/AgCl was obtained in phosphate buffer solution. The ECL assay was used for the sensitive determination of SARS-CoV-2 N protein with the linear range from 0.01 to 50 ng mL<sup>-1</sup>, and the detection limit was 3.0 pg mL<sup>-1</sup>. The immunosensor showed good reproducibility and stability, and the ECL immunoassay was used to determine the SARS-CoV-2 N protein in serum samples. The proposed approach to obtain micelles is versatile for the preparation of stable ECL luminophores by using hydrophobic materials, and the strategy provides an alternative for ECL bioassays based on the coreactant route.

Analytical ChemistryVol. 96(43)
BioClinica (United States) (US), Shaanxi Normal University (CN), Air Force Medical University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shaanxi Province
Openalex Percentile: Top 29%
Advanced biosensing and bioanalysis techniques
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.