Effect of biomechanical load factors on the stress-strain state of teeth and underlying bone tissue

Background: The biomechanical conditions under which teeth, implants, and bone tissue function clearly determine their resistance to overloading and subsequent destruction. However, mathematical modeling has not previously been used to compare functional stress in teeth across a wide range of sensitive biomechanical load conditions. Aim: To compare the stress-strain state parameters of tooth and socket tissues under various biomechanical load conditions. Materials and methods: A mathematical model was used to assess the stress-strain state parameters of dental tissue and sockets under vertical and oblique load (150N) with various modeling settings, compared to reference model parameters. The following parameters were assessed: enamel attrition, bone density reduction, bone resorption by 30% and 50%, supra-occlusion, tooth cavity, composite restoration, and ceramic inlay. Results: Enamel attrition significantly increases stress under vertical and oblique loads: 1.9 and 1.6 times for enamel, and 1.5 and 1.2 times for dentin, respectively. Tooth cavities increase stress by 1.2 and 1.8 times (enamel; vertical and oblique loads, respectively), and 1.3 times (dentin; vertical load). Increased functional load causes a proportional increase in stress in hard tooth tissues and adjacent bone tissues. Supra-occlusion causes a sharp increase in stress in the enamel, with a point stress concentration. When a tooth cavity is filled with a composite or ceramic material, the stress-strain state parameters are similar to those in intact teeth (however, the enamel still experiences a 1.5-fold increase in stress under vertical pressure). Conclusion: 3D mathematical modeling revealed a significant difference in maximum stress in tooth and socket tissues compared to normal biomechanical conditions, as well as when comparing various sensitive load conditions. Stress in tooth and bone tissues increased in all cases of abnormal biomechanical conditions, especially when oblique load was applied.

Authors

Institutions

Publication Details

Journal
Russian Journal of Dentistry
Published
2024-10-17
DOI
https://doi.org/10.17816/dent634253
Citations
2
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
0.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of biomechanical load factors on the stress-strain state of teeth and underlying bone tissue

Dmitry V. Martynov, Alexandra Viktorovna Em, Maksim S. Grishkov, Emilia A. Olesova et al.
2 citations
Russian Journal of Dentistry
Engineering Technology and Methodologies
0.70
article

Effect of biomechanical load factors on the stress-strain state of teeth and underlying bone tissue

Dmitry V. Martynov, Alexandra Viktorovna Em, Maksim S. Grishkov, Emilia A. Olesova, A. A. Ilyin
article en
2 citations

Abstract

Background: The biomechanical conditions under which teeth, implants, and bone tissue function clearly determine their resistance to overloading and subsequent destruction. However, mathematical modeling has not previously been used to compare functional stress in teeth across a wide range of sensitive biomechanical load conditions. Aim: To compare the stress-strain state parameters of tooth and socket tissues under various biomechanical load conditions. Materials and methods: A mathematical model was used to assess the stress-strain state parameters of dental tissue and sockets under vertical and oblique load (150N) with various modeling settings, compared to reference model parameters. The following parameters were assessed: enamel attrition, bone density reduction, bone resorption by 30% and 50%, supra-occlusion, tooth cavity, composite restoration, and ceramic inlay. Results: Enamel attrition significantly increases stress under vertical and oblique loads: 1.9 and 1.6 times for enamel, and 1.5 and 1.2 times for dentin, respectively. Tooth cavities increase stress by 1.2 and 1.8 times (enamel; vertical and oblique loads, respectively), and 1.3 times (dentin; vertical load). Increased functional load causes a proportional increase in stress in hard tooth tissues and adjacent bone tissues. Supra-occlusion causes a sharp increase in stress in the enamel, with a point stress concentration. When a tooth cavity is filled with a composite or ceramic material, the stress-strain state parameters are similar to those in intact teeth (however, the enamel still experiences a 1.5-fold increase in stress under vertical pressure). Conclusion: 3D mathematical modeling revealed a significant difference in maximum stress in tooth and socket tissues compared to normal biomechanical conditions, as well as when comparing various sensitive load conditions. Stress in tooth and bone tissues increased in all cases of abnormal biomechanical conditions, especially when oblique load was applied.

Russian Journal of DentistryVol. 28(5)
Ministry of Health of the Russian Federation (RU), State Scientific Center of the Russian Federation - Federal Medical Biophysical Center named after A.I. Burnazyan (RU), Stavropol State Medical University (RU)
Openalex Percentile: Top 25%
Engineering Technology and Methodologies
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.