The straight part of the corrugated steel plate (CSP) pipe-arch structure in soil may cause local buckling instability due to insufficient load-bearing capacity. Recently, composite CSP pipe-arch has been widely utilized to enhance structural stability, and their stability needs to be thoroughly investigated. This paper studies the local buckling stability problem of the straight part of composite CSP pipe-arch in soil by simplifying the soil support and introducing the inter-layer bonding effect. Based on elastic stability theory, a theoretical mechanical model of composite CSP pipe-arch was proposed. The Rayleigh–Ritz method and the semi-combined composite structure stiffness approximation were used to derive the critical buckling conditions for the straight part of the composite CSP pipe-arch. Through numerical calculation and influencing factors analysis, it is concluded that the critical buckling load of the straight part of the composite CSP pipe-arch structure is affected by the elastic modulus, thickness, Poisson’s ratio, rotational restraint stiffness and side length of the straight part of the material. In particular, it is found that as the inter-layer bonding coefficient increases, the critical buckling load is improved, while the critical buckling wave number is mainly influenced by the width of the straight part, elastic modulus, and inter-layer bonding coefficient. Additionally, we discussed the coupling effect of several key parameters on the stability of the structure. The results of this study offer theoretical foundations and guidance for the application of composite CSP pipe-arch in soil engineering, such as culverts, tunnels, and pipeline transportation.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-10-17
DOI
https://doi.org/10.3390/buildings14103290
Citations
1
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Local Stability Analysis of a Composite Corrugated Steel Plate Pipe-Arch in Soil

Feng Shi, Peng Hu, Kai Li, Junxiu Liu et al.
1 citations
Buildings
Geotechnical Engineering and Underground Structures
0.26
article

Local Stability Analysis of a Composite Corrugated Steel Plate Pipe-Arch in Soil

Feng Shi, Peng Hu, Kai Li, Junxiu Liu, Chengwen Che, Pengsen Xu
article en
1 citations

Abstract

The straight part of the corrugated steel plate (CSP) pipe-arch structure in soil may cause local buckling instability due to insufficient load-bearing capacity. Recently, composite CSP pipe-arch has been widely utilized to enhance structural stability, and their stability needs to be thoroughly investigated. This paper studies the local buckling stability problem of the straight part of composite CSP pipe-arch in soil by simplifying the soil support and introducing the inter-layer bonding effect. Based on elastic stability theory, a theoretical mechanical model of composite CSP pipe-arch was proposed. The Rayleigh–Ritz method and the semi-combined composite structure stiffness approximation were used to derive the critical buckling conditions for the straight part of the composite CSP pipe-arch. Through numerical calculation and influencing factors analysis, it is concluded that the critical buckling load of the straight part of the composite CSP pipe-arch structure is affected by the elastic modulus, thickness, Poisson’s ratio, rotational restraint stiffness and side length of the straight part of the material. In particular, it is found that as the inter-layer bonding coefficient increases, the critical buckling load is improved, while the critical buckling wave number is mainly influenced by the width of the straight part, elastic modulus, and inter-layer bonding coefficient. Additionally, we discussed the coupling effect of several key parameters on the stability of the structure. The results of this study offer theoretical foundations and guidance for the application of composite CSP pipe-arch in soil engineering, such as culverts, tunnels, and pipeline transportation.

BuildingsVol. 14(10)
Anhui Jianzhu University (CN), CCCC Highway Consultants (China) (CN)
National Natural Science Foundation of China, Natural Science Foundation of Anhui Province, University Natural Science Research Project of Anhui Province
Life in Land
Openalex Percentile: Top 44%
Geotechnical Engineering and Underground Structures
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.