Establishing Diagnostic Reference Levels for Single-Photon Emission Computed Tomography (SPECT) Imaging: A Preliminary Study in Indian Healthcare Settings

Introduction In nuclear medicine, there is a critical need to balance the control and optimization of radiation doses to ensure patient safety while achieving high-quality diagnostic outcomes. However, diagnostic reference levels (DRLs) for nuclear medicine imaging studies have not been established in India. This study aims to fill this gap by establishing institutional DRLs and assessing radiation dose data specifically for Nuclear Medicine SPECT examinations. Methods This research was a cross-sectional observational study conducted in a single tertiary care setting, involving 1,250 patients. Data on the administered activity for 18 common single photon emission computed tomography (SPECT) procedures were gathered from 2019 to 2021. The 75th percentile (Q3) was established as the baseline for the institutional DRLs. Furthermore, the study conducted comparative analyses with established international DRLs. Results The study proposed institutional DRLs based on 18 SPECT nuclear medicine imaging examinations. The highest Q3 DRLs were identified for 99mTc-sestamibi (1193 MBq), followed by 99mTc-methylene diphosphonate (747 MBq) and 99mTc-ethyl cysteinate dimer (608 MBq). The lowest DRL was recorded for 99mTc gastric emptying imaging (37 MBq). Comparisons with international DRLs indicated close alignment with European Association of Nuclear Medicine Medical Internal Radiation Dose guidelines, while DRLs set by the National Council on Radiation Protection and Measurements (NCRP) were identified as distinct in several key aspects when compared to other established DRLs. Conclusion This research marks a significant step toward standardizing SPECT procedure doses in India, contributing to improved patient safety and care in nuclear medicine. The established DRLs will enhance the optimization of administered activities, ensure adherence to international standards, and improve diagnostic quality while reducing radiation exposure. These institutional DRLs will serve as the foundation for developing a roadmap to establish national DRLs.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-10-17
DOI
https://doi.org/10.7759/cureus.71740
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing Diagnostic Reference Levels for Single-Photon Emission Computed Tomography (SPECT) Imaging: A Preliminary Study in Indian Healthcare Settings

Prabhakar Mishra, Mayank Goswami, Vandana Dhingra, Pankaj Sharma et al.
Cureus
Radiation Dose and Imaging
article

Establishing Diagnostic Reference Levels for Single-Photon Emission Computed Tomography (SPECT) Imaging: A Preliminary Study in Indian Healthcare Settings

Prabhakar Mishra, Mayank Goswami, Vandana Dhingra, Pankaj Sharma, Ashutosh Pandey
article en

Abstract

Introduction In nuclear medicine, there is a critical need to balance the control and optimization of radiation doses to ensure patient safety while achieving high-quality diagnostic outcomes. However, diagnostic reference levels (DRLs) for nuclear medicine imaging studies have not been established in India. This study aims to fill this gap by establishing institutional DRLs and assessing radiation dose data specifically for Nuclear Medicine SPECT examinations. Methods This research was a cross-sectional observational study conducted in a single tertiary care setting, involving 1,250 patients. Data on the administered activity for 18 common single photon emission computed tomography (SPECT) procedures were gathered from 2019 to 2021. The 75th percentile (Q3) was established as the baseline for the institutional DRLs. Furthermore, the study conducted comparative analyses with established international DRLs. Results The study proposed institutional DRLs based on 18 SPECT nuclear medicine imaging examinations. The highest Q3 DRLs were identified for 99mTc-sestamibi (1193 MBq), followed by 99mTc-methylene diphosphonate (747 MBq) and 99mTc-ethyl cysteinate dimer (608 MBq). The lowest DRL was recorded for 99mTc gastric emptying imaging (37 MBq). Comparisons with international DRLs indicated close alignment with European Association of Nuclear Medicine Medical Internal Radiation Dose guidelines, while DRLs set by the National Council on Radiation Protection and Measurements (NCRP) were identified as distinct in several key aspects when compared to other established DRLs. Conclusion This research marks a significant step toward standardizing SPECT procedure doses in India, contributing to improved patient safety and care in nuclear medicine. The established DRLs will enhance the optimization of administered activities, ensure adherence to international standards, and improve diagnostic quality while reducing radiation exposure. These institutional DRLs will serve as the foundation for developing a roadmap to establish national DRLs.

CureusVol. 16(10)
Indian Institute of Technology Roorkee (IN), Sanjay Gandhi Post Graduate Institute of Medical Sciences (IN), Seema Dental College and Hospital (IN), All India Institute of Medical Sciences Rishikesh (IN)
Indian Institute of Technology Roorkee
Openalex Percentile: Top 70%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.