Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function

Background and Objectives The Valsalva test, although commonly utilized to assess the Eustachian tube function, is limited by drawbacks such as inconsistent pressure increases in the nasal cavity. Thus we introduced the “Popper test,” a tympanic membrane inflation test using the automatic middle ear inflation device known as middle ear inflation device (MEID), to explore its viability as an alternative to the Valsalva test.Subjects and Method We sampled 80 ears from patients between June 1, 2023, and August 1, 2023. Each patient underwent both the Valsalva and Popper tests using the MEID. Participants were divided into three categories: the “unable” group (patients who could not follow the Valsalva maneuver) and the “successful” and “unsuccessful” groups (patients whose attempts at the Valsalva or Popper tests either successed or failed). Success or failure was determined using an otoscope to assess the bulging of the tympanic membrane.Results Of the 68 ears with normal middle ear pressure, 30.9% (21 ears) showed an inability to perform the Valsalva test, 45.6% (31 ears) successfully inflated the tympanic membrane via the Valsalva test, and 23.5% (16 ears) failed. Conversely, the Popper test resulted in an 88.2% (60 ears) success rate for inflating the tympanic membrane, with only 11.8% (8 ears) failing.Conclusion Variability observed in the Valsalva test outcomes may be attributed to individual differences and the instructor’s technique. MEID, as utilized in the Popper test, offers a promising alternative to the Valsalva test, potentially enhancing the reliability by minimizing individual variation. However, the diagnostic performance may be dependent on the properties of the MEID.

Authors

Publication Details

Journal
Korean Journal of Otorhinolaryngology - Head and Neck Surgery
Published
2024-10-16
DOI
https://doi.org/10.3342/kjorl-hns.2024.00255
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function

Dae Hyun Kim, Moon Su Kwak, Ju Ha Park, Seong Hoon Bae
Korean Journal of Otorhinolaryngology - Head and Neck Surgery
Particle accelerators and beam dynamics
article

Evaluation of the Popper Test as an Alternative to the Valsalva Maneuver for Assessing Eustachian Tube Function

Dae Hyun Kim, Moon Su Kwak, Ju Ha Park, Seong Hoon Bae
article en

Abstract

Background and Objectives The Valsalva test, although commonly utilized to assess the Eustachian tube function, is limited by drawbacks such as inconsistent pressure increases in the nasal cavity. Thus we introduced the “Popper test,” a tympanic membrane inflation test using the automatic middle ear inflation device known as middle ear inflation device (MEID), to explore its viability as an alternative to the Valsalva test.Subjects and Method We sampled 80 ears from patients between June 1, 2023, and August 1, 2023. Each patient underwent both the Valsalva and Popper tests using the MEID. Participants were divided into three categories: the “unable” group (patients who could not follow the Valsalva maneuver) and the “successful” and “unsuccessful” groups (patients whose attempts at the Valsalva or Popper tests either successed or failed). Success or failure was determined using an otoscope to assess the bulging of the tympanic membrane.Results Of the 68 ears with normal middle ear pressure, 30.9% (21 ears) showed an inability to perform the Valsalva test, 45.6% (31 ears) successfully inflated the tympanic membrane via the Valsalva test, and 23.5% (16 ears) failed. Conversely, the Popper test resulted in an 88.2% (60 ears) success rate for inflating the tympanic membrane, with only 11.8% (8 ears) failing.Conclusion Variability observed in the Valsalva test outcomes may be attributed to individual differences and the instructor’s technique. MEID, as utilized in the Popper test, offers a promising alternative to the Valsalva test, potentially enhancing the reliability by minimizing individual variation. However, the diagnostic performance may be dependent on the properties of the MEID.

Korean Journal of Otorhinolaryngology - Head and Neck SurgeryVol. 68(2)
Yonsei University, Yonsei University College of Medicine
Openalex Percentile: Top 72%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.