Analysis of Heartbeat Signals to Detect Sleep Disorders Using Artificial Neural Network Methods

A human sleep disorder detection system has been designed using an AD8232 Electrocardiogram sensor module integrated with a microcontroller and internet connection through ESP 32. The heartbeat signals from the sensor are analyzed using Artificial Neural Network (ANN) methods to determine normal conditions, Obstructive Sleep Apnea (OSA), or Central Sleep Apnea (CSA). The sensor's accuracy was measured over 10 measurements, resulting in 96.85%. Testing with 30 training data samples achieved an accuracy of 93.33%, and testing with 20 training data samples achieved an accuracy of 80%. The system displays output values through the Internet of Things (IoT) with an average computation time of around 7.6 ms.

Authors

Institutions

Publication Details

Journal
Komputasi Jurnal Ilmiah Ilmu Komputer dan Matematika
Published
2024-08-12
DOI
https://doi.org/10.33751/komputasi.v21i2.10222
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Heartbeat Signals to Detect Sleep Disorders Using Artificial Neural Network Methods

Teguh Puja Negara, Moch Aripin, Soewarto Hardhienata
Komputasi Jurnal Ilmiah Ilmu Komputer dan Matematika
Non-Invasive Vital Sign Monitoring
article

Analysis of Heartbeat Signals to Detect Sleep Disorders Using Artificial Neural Network Methods

Teguh Puja Negara, Moch Aripin, Soewarto Hardhienata
article en

Abstract

A human sleep disorder detection system has been designed using an AD8232 Electrocardiogram sensor module integrated with a microcontroller and internet connection through ESP 32. The heartbeat signals from the sensor are analyzed using Artificial Neural Network (ANN) methods to determine normal conditions, Obstructive Sleep Apnea (OSA), or Central Sleep Apnea (CSA). The sensor's accuracy was measured over 10 measurements, resulting in 96.85%. Testing with 30 training data samples achieved an accuracy of 93.33%, and testing with 20 training data samples achieved an accuracy of 80%. The system displays output values through the Internet of Things (IoT) with an average computation time of around 7.6 ms.

Komputasi Jurnal Ilmiah Ilmu Komputer dan MatematikaVol. 21(2)
Pakuan University (ID)
Openalex Percentile: Top 83%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.