A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study

The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw. The second and third groups each had 5 straight cemented crowns attached to a tapered abutment with flat-slotted and internal hex abutment screws, respectively. Samples were subjected to a static cyclic load until failure. Kruskal-Wallis H, Dunn, and one-way analysis of variance with Tukey honestly significant difference tests were performed. Cemented straight crowns supported by an angled abutment connected to implants with flat-slotted and internal hex abutment screw heads failed at an average of 4.24 × 106 cycles ± 3.31 SD and 12.67 × 106 cycles ± 5.47 SD, respectively. Cemented angled crowns supported by a straight abutment connected to identical implants with an external hex abutment screw survived 18.02 × 106 cycles ± 4.49 SD. The periotest value rate of change increased at a higher rate in crowns supported by angled abutments compared with straight abutments (p < .05). No cement failure was observed. Under the experimental conditions, larger abutment screw head sizes demonstrated greater stability of the abutment-abutment screw joint interface. Based on the in vitro findings, no cement failure was observed between the cemented crown and abutment connection. Future research with standardized comparative setups and larger sample sizes is needed.

Authors

Institutions

Publication Details

Journal
Journal of Oral Implantology
Published
2024-10-16
DOI
https://doi.org/10.1563/aaid-joi-d-24-00128
Citations
3
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.48
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study

Jan C. Kwan
3 citations
Journal of Oral Implantology
Dental Implant Techniques and Outcomes
1.48
article

A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study

Jan C. Kwan
article en
3 citations

Abstract

The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw. The second and third groups each had 5 straight cemented crowns attached to a tapered abutment with flat-slotted and internal hex abutment screws, respectively. Samples were subjected to a static cyclic load until failure. Kruskal-Wallis H, Dunn, and one-way analysis of variance with Tukey honestly significant difference tests were performed. Cemented straight crowns supported by an angled abutment connected to implants with flat-slotted and internal hex abutment screw heads failed at an average of 4.24 × 106 cycles ± 3.31 SD and 12.67 × 106 cycles ± 5.47 SD, respectively. Cemented angled crowns supported by a straight abutment connected to identical implants with an external hex abutment screw survived 18.02 × 106 cycles ± 4.49 SD. The periotest value rate of change increased at a higher rate in crowns supported by angled abutments compared with straight abutments (p < .05). No cement failure was observed. Under the experimental conditions, larger abutment screw head sizes demonstrated greater stability of the abutment-abutment screw joint interface. Based on the in vitro findings, no cement failure was observed between the cemented crown and abutment connection. Future research with standardized comparative setups and larger sample sizes is needed.

Journal of Oral ImplantologyVol. 50(6)
McGill University Health Centre (CA), McGill University (CA)
Openalex Percentile: Top 18%
Dental Implant Techniques and Outcomes
1.48
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive Forces: An In Vitro Pilot Study — Jan C. Kwan · Journal of Oral Implantology (2024) | TGRS Research Map | TGRS