Analisis Pengaruh Faktor Meteorologi Terhadap Konsentrasi Gas SO2 dan NO2 dari Cerobong Ketel Pabrik Gula X

The process of burning bagasse in a steam boiler produces pollutants in the form of exhaust gas emissions through the chimney, which can pollute air quality and harm health. The aim of this study is to determine the great influence of meteorological factors including exhaust gas temperature, air temperature, and flow speed in 4 areas of the boiler pipe that can affect the load of SO2 and NO2 gas pollutants through statistical data analysis. The ANOVA test used in this study was the ANOVA One Way test. The results of the study showed that there was a significant influence of the air temperature factor on SO2 in Boiler 4 / Cheng Chen with a value of F value 14,553 and a sig value of 0,032, as well as the influence that exists on the exhaust gas temperature factor and air temperature on NO2 in Stork Boiler 2 with an F value of 15,358 ; 17,889 and a sig value of 0.030 ; 0.024. The results of the analysis can be used as monitoring to evaluate the success rate and operational efficiency of the boiler under the management that has been carried out.

Authors

Institutions

Publication Details

Journal
Media Ilmiah Teknik Lingkungan
Published
2024-09-27
DOI
https://doi.org/10.33084/mitl.v9i2.7177
Primary Topic
Heavy Metal Pollution Remediation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Pengaruh Faktor Meteorologi Terhadap Konsentrasi Gas SO2 dan NO2 dari Cerobong Ketel Pabrik Gula X

Mareta Fifianah, Aussie Amalia
Media Ilmiah Teknik Lingkungan
Heavy Metal Pollution Remediation
article

Analisis Pengaruh Faktor Meteorologi Terhadap Konsentrasi Gas SO2 dan NO2 dari Cerobong Ketel Pabrik Gula X

Mareta Fifianah, Aussie Amalia
article en

Abstract

The process of burning bagasse in a steam boiler produces pollutants in the form of exhaust gas emissions through the chimney, which can pollute air quality and harm health. The aim of this study is to determine the great influence of meteorological factors including exhaust gas temperature, air temperature, and flow speed in 4 areas of the boiler pipe that can affect the load of SO2 and NO2 gas pollutants through statistical data analysis. The ANOVA test used in this study was the ANOVA One Way test. The results of the study showed that there was a significant influence of the air temperature factor on SO2 in Boiler 4 / Cheng Chen with a value of F value 14,553 and a sig value of 0,032, as well as the influence that exists on the exhaust gas temperature factor and air temperature on NO2 in Stork Boiler 2 with an F value of 15,358 ; 17,889 and a sig value of 0.030 ; 0.024. The results of the analysis can be used as monitoring to evaluate the success rate and operational efficiency of the boiler under the management that has been carried out.

Media Ilmiah Teknik LingkunganVol. 9(2)
University of Pembangunan Nasional Veteran Jawa Timur (ID)
Openalex Percentile: Top 83%
Heavy Metal Pollution Remediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analisis Pengaruh Faktor Meteorologi Terhadap Konsentrasi Gas SO2 dan NO2 dari Cerobong Ketel Pabrik Gula X — Mareta Fifianah, Aussie Amalia · Media Ilmiah Teknik Lingkungan (2024) | TGRS Research Map | TGRS