Thermal Performance of a Laminar Flow Double Pipe Heat Exchanger with Spiral Airfoil Inserts

Objective: This study evaluates the thermal performance of a double-pipe heat exchanger using a spiral airfoil insert in the inner pipe. Methods: The enhancement technique is classified as a passive method, as it does not require the direct application of external power to improve the heat transfer coefficient. Spiral pitch ratios of P/D=7, 5, and 3 were used, with the Reynolds number (Re) varying within the laminar flow regime (Re ≤ 2,100). Cold water flows inside the inner pipe, while hot water flows counter to it in the annulus. Results: The experimental results show that the Nusselt number increased by 159%, 161%, and 171%, respectively, compared to a smooth pipe alone, for flow rates of 2L/min, 2.5L/min, and 3L/min. Additionally, the highest friction factor reached 142%. Conclusion: The results indicate that the best performance evaluation criterion (PEC) was achieved within the flow range of 2L/min to 3L/min, with a pitch insertion of 3, yielding a PEC of 158% to 152%, respectively.

Authors

Publication Details

Journal
Journal of Modern Industry and Manufacturing
Published
2024-10-16
DOI
https://doi.org/10.53964/jmim.2024010
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Performance of a Laminar Flow Double Pipe Heat Exchanger with Spiral Airfoil Inserts

Hussein Hayder Mohammed Alı, Khaled Yahya Shimer
Journal of Modern Industry and Manufacturing
Heat Transfer and Optimization
article

Thermal Performance of a Laminar Flow Double Pipe Heat Exchanger with Spiral Airfoil Inserts

Hussein Hayder Mohammed Alı, Khaled Yahya Shimer
article en

Abstract

Objective: This study evaluates the thermal performance of a double-pipe heat exchanger using a spiral airfoil insert in the inner pipe. Methods: The enhancement technique is classified as a passive method, as it does not require the direct application of external power to improve the heat transfer coefficient. Spiral pitch ratios of P/D=7, 5, and 3 were used, with the Reynolds number (Re) varying within the laminar flow regime (Re ≤ 2,100). Cold water flows inside the inner pipe, while hot water flows counter to it in the annulus. Results: The experimental results show that the Nusselt number increased by 159%, 161%, and 171%, respectively, compared to a smooth pipe alone, for flow rates of 2L/min, 2.5L/min, and 3L/min. Additionally, the highest friction factor reached 142%. Conclusion: The results indicate that the best performance evaluation criterion (PEC) was achieved within the flow range of 2L/min to 3L/min, with a pitch insertion of 3, yielding a PEC of 158% to 152%, respectively.

Journal of Modern Industry and ManufacturingVol. 3
Affordable and clean energy
Openalex Percentile: Top 82%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.