Effect of crown seating methods on the remnant cement in the subgingival region of a cement-retained implant crown

This study aimed to investigate the effects of crown seating speed, crown seating force, quantity of cement used, and type of implant cement on the amount of remnant cement in the subgingival region (RCS) after cementation. Cement-retained implant crowns were cemented to titanium abutments using the following methods: four types of implant cement (TBN: TEMP BOND NE, NR: NEXUS RMGI, ME: MAXCEM ELITE, and U200: RELYX U200), three quantities of cement (0.02 ml, 0.04 ml, and 0.06 ml), three crown seating speeds (5 mm/s, 10 mm/s, and 15 mm/s), and two crown seating forces (25 N, 50 N). The surface area and length of the RCS were measured using a 3D intraoral scanner. The total RCS weight was measured using an analytical balance. The RCS increased significantly as the seating speed increased, the seating force increased, and the quantity of cement increased (p < 0.05). The RCS values were the highest for TBN, followed by U200, NR, and ME (p < 0.05). The lower seating speed, smaller quantity of cement used, and smaller seating force applied in cement-retained implant restorations minimized the RCS in cement-retained prostheses. The type of cement is a factor that determines the aspects of the RCS.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-16
DOI
https://doi.org/10.1038/s41598-024-73806-w
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of crown seating methods on the remnant cement in the subgingival region of a cement-retained implant crown

Hwiseong Oh, Jae‐Jun Ryu, Jeong‐Yol Lee, Ji Suk Shim et al.
Scientific Reports
Dental Implant Techniques and Outcomes
article

Effect of crown seating methods on the remnant cement in the subgingival region of a cement-retained implant crown

Hwiseong Oh, Jae‐Jun Ryu, Jeong‐Yol Lee, Ji Suk Shim, Fanghui Ji
article en

Abstract

This study aimed to investigate the effects of crown seating speed, crown seating force, quantity of cement used, and type of implant cement on the amount of remnant cement in the subgingival region (RCS) after cementation. Cement-retained implant crowns were cemented to titanium abutments using the following methods: four types of implant cement (TBN: TEMP BOND NE, NR: NEXUS RMGI, ME: MAXCEM ELITE, and U200: RELYX U200), three quantities of cement (0.02 ml, 0.04 ml, and 0.06 ml), three crown seating speeds (5 mm/s, 10 mm/s, and 15 mm/s), and two crown seating forces (25 N, 50 N). The surface area and length of the RCS were measured using a 3D intraoral scanner. The total RCS weight was measured using an analytical balance. The RCS increased significantly as the seating speed increased, the seating force increased, and the quantity of cement increased (p < 0.05). The RCS values were the highest for TBN, followed by U200, NR, and ME (p < 0.05). The lower seating speed, smaller quantity of cement used, and smaller seating force applied in cement-retained implant restorations minimized the RCS in cement-retained prostheses. The type of cement is a factor that determines the aspects of the RCS.

Scientific ReportsVol. 14(1)
Korea University (KR), Korea University Medical Center (KR), Korea University (JP), Naver (South Korea) (KR)
National Research Foundation, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Sustainable cities and communities
Openalex Percentile: Top 74%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of crown seating methods on the remnant cement in the subgingival region of a cement-retained implant crown — Hwiseong Oh, Jae‐Jun Ryu, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS