Fast-switching and fast-throwing technology for open loop points of the power grid and its application in the regional power grid

Fast-switching and fast-throwing device is installed at different open loop points of power supply in the power grid, which can provide backup power source for neighbouring supply zones and has important practical value of the reliability improvment of power syetem. The amplitudes and phase angles of voltages measured at two adjacent busbars are different because both sides of the loop closing positon power system are powered by different power sources. The most obvious impact of loop closing operation is the system disturbance and impact current. Therefore, the constraint condition of loop closing is analyzed, and the technical scheme for the fast-switching device is determined. The practicality of the fast-switching and fast-throwing technology applied at the loop closing position between neighbouring supply zones is verified based on the transient simulation data from regional power system of Baotou, China.

Authors

Institutions

Publication Details

Published
2024-10-16
DOI
https://doi.org/10.1117/12.3033401
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast-switching and fast-throwing technology for open loop points of the power grid and its application in the regional power grid

Kai Guan, Zhang Na, Ren Mu, Haitao Song et al.
High-Voltage Power Transmission Systems
article

Fast-switching and fast-throwing technology for open loop points of the power grid and its application in the regional power grid

Kai Guan, Zhang Na, Ren Mu, Haitao Song, Xueniu Zhan
article en

Abstract

Fast-switching and fast-throwing device is installed at different open loop points of power supply in the power grid, which can provide backup power source for neighbouring supply zones and has important practical value of the reliability improvment of power syetem. The amplitudes and phase angles of voltages measured at two adjacent busbars are different because both sides of the loop closing positon power system are powered by different power sources. The most obvious impact of loop closing operation is the system disturbance and impact current. Therefore, the constraint condition of loop closing is analyzed, and the technical scheme for the fast-switching device is determined. The practicality of the fast-switching and fast-throwing technology applied at the loop closing position between neighbouring supply zones is verified based on the transient simulation data from regional power system of Baotou, China.

Inner Mongolia Electric Power (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast-switching and fast-throwing technology for open loop points of the power grid and its application in the regional power grid — Kai Guan, Zhang Na, et al. · (2024) | TGRS Research Map | TGRS