Development of a low energy loss micro-channel plate based position-sensitive detector for the Rare Radio-Isotope Ring

A position-sensitive micro-channel plate type detector has been developed for use in the Rare Radio-Isotope Ring at RIKEN, Japan. It uses secondary electrons emitted from a conversion foil and deflected at 90° to create a position signal. Design constraints included operation in a high-vacuum, a large area to cover the ring acceptance and low beam interaction to reduce energy loss. It must achieve a precision sufficient to measure the in-ring dispersion and perform position diagnostics for tuning the injection. Reducing the time-of-flight of secondary electrons was principal in improving resolution as it reduces their final Gaussian spread. This was implemented by compacting the geometry of the detector and raising the acceleration potential. Electric field homogeneity was also improved by decreasing the electrostatic grid wire pitch from 2 mm to 1 mm. Offline tests with alpha sources and online tests with a 200 MeV/u 84 Kr beam were conducted, reaching a final average position resolution of σ = 1.3 mm. This is sufficient for conducting beam diagnostics in the storage ring. • A position-sensitive detector designed for low beam energy loss was developed. • Decreasing secondary electron time of flight was key for improving resolution. • Resolution was improved by reducing the detector size. • Resolution was improved by increasing the acceleration potential. • The resolution was sufficient for diagnostics of the kicker injection magnet.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2024-10-16
DOI
https://doi.org/10.1016/j.nima.2024.169980
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a low energy loss micro-channel plate based position-sensitive detector for the Rare Radio-Isotope Ring

Y. Yamaguchi, S. Naimi, Т. Уесака, Shinji Suzuki et al.
1 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Atomic and Subatomic Physics Research
0.34
article

Development of a low energy loss micro-channel plate based position-sensitive detector for the Rare Radio-Isotope Ring

Y. Yamaguchi, S. Naimi, Т. Уесака, Shinji Suzuki, H. F. Li, M. Mukai, Asahi Yano, D. Nagae, George Hudson-chang, Takayuki Yamaguchi, T. Moriguchi, Y. Abe, A. Ozawa, Robert K. Crane
article en
1 citations

Abstract

A position-sensitive micro-channel plate type detector has been developed for use in the Rare Radio-Isotope Ring at RIKEN, Japan. It uses secondary electrons emitted from a conversion foil and deflected at 90° to create a position signal. Design constraints included operation in a high-vacuum, a large area to cover the ring acceptance and low beam interaction to reduce energy loss. It must achieve a precision sufficient to measure the in-ring dispersion and perform position diagnostics for tuning the injection. Reducing the time-of-flight of secondary electrons was principal in improving resolution as it reduces their final Gaussian spread. This was implemented by compacting the geometry of the detector and raising the acceleration potential. Electric field homogeneity was also improved by decreasing the electrostatic grid wire pitch from 2 mm to 1 mm. Offline tests with alpha sources and online tests with a 200 MeV/u 84 Kr beam were conducted, reaching a final average position resolution of σ = 1.3 mm. This is sufficient for conducting beam diagnostics in the storage ring. • A position-sensitive detector designed for low beam energy loss was developed. • Decreasing secondary electron time of flight was key for improving resolution. • Resolution was improved by reducing the detector size. • Resolution was improved by increasing the acceleration potential. • The resolution was sufficient for diagnostics of the kicker injection magnet.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1069
Centre National de la Recherche Scientifique (FR), University of Tsukuba (JP), Chinese Academy of Sciences (CN), Université Paris-Saclay (FR), University of Surrey (GB), Institute of Modern Physics (CN), Institut National de Physique Nucléaire et de Physique des Particules (FR), Laboratoire de Physique des 2 Infinis Irène Joliot-Curie (FR), RIKEN Nishina Center (JP), Saitama University (JP)
Japan Society for the Promotion of Science London, National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 39%
Atomic and Subatomic Physics Research
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.