Computational multiphase mixture simulations of a two-phase R-744 ejector geometry in transcritical R-744 heat pump applications

Purpose Two-phase R-744 ejectors are critical components enabling energy recovery in R-744 heat pump and refrigeration systems, but despite their simple geometry, the flow physics involve complex multiphase mixing phenomena that need to be well-quantified for component and overall system improvement. This study aims to report on multiphase mixture simulations for a specific two-phase R-744 ejector with supercritical inlet conditions at the motive inlet side. Design/methodology/approach Four different operating conditions, which have motive inlet pressure range of 90.1 bar–101.1 bar, are selected from an existing experimental data set. A two-phase thermodynamic equilibrium (TPTE) model is used, where the fluid properties are described by a thermodynamic look-up table. Findings The results show that the TPTE model overpredicts mass flow rates at the motive inlet, resulting in a relative error ranging from 15.6% to 21.7%. For the mass flow rate at the suction inlet, the relative errors are found less than 1.5% for three cases, while the last case has an error of 12.4%. The maximum deviation of the mass entrainment ratio is found to be 8.0% between the TPTE model and the experimental data. Ejector efficiency ranges from 25.4% to 28.0%. A higher pressure difference between the ejector outlet and the diverging nozzle exit provides greater pressure lift. Research limitations/implications Based on the results, near future efforts will be to optimize estimation errors while enabling more detailed field analysis of pressure, density, temperature and enthalpy in the computational domain. Originality/value The authors have two main original contributions: 1) the presented thermodynamic look-up table is unique and provides unique computation for the real-scale ejector domain. It was created by the authors and has not been applied before as far as we know. 2) To the best of the authors’ knowledge, this study is the first study that applies the STAR-CCM+ multiphase mixture model for R-744 mixture phenomena in heat pumps and refrigeration systems.

Authors

Institutions

Publication Details

Journal
International Journal of Numerical Methods for Heat &amp Fluid Flow
Published
2024-10-16
DOI
https://doi.org/10.1108/hff-01-2024-0006
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational multiphase mixture simulations of a two-phase R-744 ejector geometry in transcritical R-744 heat pump applications

Jens Honoré Walther, Barış Burak Kanbur, Wiebke Brix Markussen, Jóhannes Kristófersson et al.
International Journal of Numerical Methods for Heat &amp Fluid Flow
Refrigeration and Air Conditioning Technologies
article

Computational multiphase mixture simulations of a two-phase R-744 ejector geometry in transcritical R-744 heat pump applications

Jens Honoré Walther, Barış Burak Kanbur, Wiebke Brix Markussen, Jóhannes Kristófersson, Alexander Busch, Ekaterini E. Kriezi, Martin Ryhl Kærn
article en

Abstract

Purpose Two-phase R-744 ejectors are critical components enabling energy recovery in R-744 heat pump and refrigeration systems, but despite their simple geometry, the flow physics involve complex multiphase mixing phenomena that need to be well-quantified for component and overall system improvement. This study aims to report on multiphase mixture simulations for a specific two-phase R-744 ejector with supercritical inlet conditions at the motive inlet side. Design/methodology/approach Four different operating conditions, which have motive inlet pressure range of 90.1 bar–101.1 bar, are selected from an existing experimental data set. A two-phase thermodynamic equilibrium (TPTE) model is used, where the fluid properties are described by a thermodynamic look-up table. Findings The results show that the TPTE model overpredicts mass flow rates at the motive inlet, resulting in a relative error ranging from 15.6% to 21.7%. For the mass flow rate at the suction inlet, the relative errors are found less than 1.5% for three cases, while the last case has an error of 12.4%. The maximum deviation of the mass entrainment ratio is found to be 8.0% between the TPTE model and the experimental data. Ejector efficiency ranges from 25.4% to 28.0%. A higher pressure difference between the ejector outlet and the diverging nozzle exit provides greater pressure lift. Research limitations/implications Based on the results, near future efforts will be to optimize estimation errors while enabling more detailed field analysis of pressure, density, temperature and enthalpy in the computational domain. Originality/value The authors have two main original contributions: 1) the presented thermodynamic look-up table is unique and provides unique computation for the real-scale ejector domain. It was created by the authors and has not been applied before as far as we know. 2) To the best of the authors’ knowledge, this study is the first study that applies the STAR-CCM+ multiphase mixture model for R-744 mixture phenomena in heat pumps and refrigeration systems.

International Journal of Numerical Methods for Heat &amp Fluid FlowVol. 35(6)
Danish Technological Institute (DK), Danfoss (Denmark) (DK), Technical University of Denmark (DK)
Affordable and clean energy
Openalex Percentile: Top 82%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.