Wide FOV metalens for near‐infrared capsule endoscopy: advancing compact medical imaging

This study presents the design, fabrication, and characterization of a wide field-of-view (FOV) metalens optimized for capsule endoscopy. The metalens achieved a 165° FOV with a high modulation transfer function (MTF) of 300 lines per millimeter (lp/mm) across the entire FOV, operating in the near-infrared (NIR) narrow-bandpass imaging at 940 nm. The performance of the metalens-based system is evaluated using two bandwidths, 12 nm and 32 nm, showing MTF values of 0.2 and 0.3 at 250 lp/mm, respectively. The metalens-based system maintains a compact form factor with a total track length of 1.4 mm and a diameter of 1.58 mm. Compared to a traditional 108° FOV endoscope, the nano-optic capsule endoscope demonstrated superior performance in terms of FOV, contrast, and resolution. This advancement represents a significant step toward enhancing diagnostic capabilities in medical imaging, offering improved performance in a more compact package compared to conventional optics.

Authors

Institutions

Publication Details

Journal
Nanophotonics
Published
2024-10-16
DOI
https://doi.org/10.1515/nanoph-2024-0393
Citations
13
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
6.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wide FOV metalens for near‐infrared capsule endoscopy: advancing compact medical imaging

Fahimeh Abrinaei, Mojtaba Moghaddasi, Bin Hu, Danni Ye et al.
13 citations
Nanophotonics
Gastrointestinal Bleeding Diagnosis and Treatment
6.03
article

Wide FOV metalens for near‐infrared capsule endoscopy: advancing compact medical imaging

Fahimeh Abrinaei, Mojtaba Moghaddasi, Bin Hu, Danni Ye, Ziming Ren, Abdul Jalal, D. Flores, Xudong Wu, Erik Edilson Perez Coca
article en
13 citations

Abstract

This study presents the design, fabrication, and characterization of a wide field-of-view (FOV) metalens optimized for capsule endoscopy. The metalens achieved a 165° FOV with a high modulation transfer function (MTF) of 300 lines per millimeter (lp/mm) across the entire FOV, operating in the near-infrared (NIR) narrow-bandpass imaging at 940 nm. The performance of the metalens-based system is evaluated using two bandwidths, 12 nm and 32 nm, showing MTF values of 0.2 and 0.3 at 250 lp/mm, respectively. The metalens-based system maintains a compact form factor with a total track length of 1.4 mm and a diameter of 1.58 mm. Compared to a traditional 108° FOV endoscope, the nano-optic capsule endoscope demonstrated superior performance in terms of FOV, contrast, and resolution. This advancement represents a significant step toward enhancing diagnostic capabilities in medical imaging, offering improved performance in a more compact package compared to conventional optics.

NanophotonicsVol. 13(24)
Beijing Institute of Technology (CN), Islamic Azad University South Tehran Branch (IR), Beijing University of Chinese Medicine (CN), Islamic Azad University North Tehran Branch (IR), Beijing Electronic Science and Technology Institute (CN), Islamic Azad University Central Tehran Branch (IR), Science and Technology on Surface Physics and Chemistry Laboratory (CN)
Beijing Municipal Natural Science Foundation, National Key Research and Development Program of China
Openalex Percentile: Top 3%
Gastrointestinal Bleeding Diagnosis and Treatment
6.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.