COMPARATIVE EVALUATION OF HARDNESS AND SURFACE ROUGHNESS AFTER DIFFERENT COOLING PROCEDURES OF HEAT CURE DENTURE BASE MATERIALS

Aim: To evaluate the influence of different cooling procedures on mechanical properties of DPI & LUCITONE heat cure poly methyl methacrylate denturebase materials before andafter 1year of brushing simulation. Materials And Methods: A total of 100 specimens were prepared using two heat cure denture base materials i.e, DPI and LUCITONE. The specimens in each group were subdivided into five groups (n=10 ) based on the cooling procedure followed: A: Flask remains in water bath till room temperature B: Remove flask from water bath, bench cool for 30min and then cool under running water for 15min C: Remove flask from water bath, bench cool for 10min and then cool under running water for 15min D: Remove flask from water bath and bench cool till room temperature E: Remove the flask from water bath and cool under running water for 15 minutes.After finishing and polishing, samples were placed in a brushing machine to simulate one year of mechanical cleansing. The specimens were tested for surface roughness with profilometer and hardness with Vickers hardness tester before and after brushing. Results were statistically analysed by two and one- way Analysis of variance (ANOVA) plus Tukey post hoc tests. Results: Specimens with type C(Remove flask from water bath, bench cool for 10min and then cool under running water for 15min)cooling procedures have high hardness values, among whichLucitone showed better properties. Surface roughness did not show significant changes among different groups. Brushing did not significantly affect surface roughness and hardness of denture base materials. Conclusion: Two of the treatments tested, Treatment C: bench-cooling for 10 min and cooling under running water for 15min and Treatment A: cooling in water-bath till room temperature provided the highest hardness values.

Authors

Publication Details

Journal
International Journal of Advanced Research
Published
2024-09-30
DOI
https://doi.org/10.21474/ijar01/19526
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARATIVE EVALUATION OF HARDNESS AND SURFACE ROUGHNESS AFTER DIFFERENT COOLING PROCEDURES OF HEAT CURE DENTURE BASE MATERIALS

R. S. Bindu, P. Shameen Kumar, P. Akhila, Kommu Vasudha et al.
International Journal of Advanced Research
Dental materials and restorations
article

COMPARATIVE EVALUATION OF HARDNESS AND SURFACE ROUGHNESS AFTER DIFFERENT COOLING PROCEDURES OF HEAT CURE DENTURE BASE MATERIALS

R. S. Bindu, P. Shameen Kumar, P. Akhila, Kommu Vasudha, P. Deepthi, Y. Ravi Shankar
article en

Abstract

Aim: To evaluate the influence of different cooling procedures on mechanical properties of DPI & LUCITONE heat cure poly methyl methacrylate denturebase materials before andafter 1year of brushing simulation. Materials And Methods: A total of 100 specimens were prepared using two heat cure denture base materials i.e, DPI and LUCITONE. The specimens in each group were subdivided into five groups (n=10 ) based on the cooling procedure followed: A: Flask remains in water bath till room temperature B: Remove flask from water bath, bench cool for 30min and then cool under running water for 15min C: Remove flask from water bath, bench cool for 10min and then cool under running water for 15min D: Remove flask from water bath and bench cool till room temperature E: Remove the flask from water bath and cool under running water for 15 minutes.After finishing and polishing, samples were placed in a brushing machine to simulate one year of mechanical cleansing. The specimens were tested for surface roughness with profilometer and hardness with Vickers hardness tester before and after brushing. Results were statistically analysed by two and one- way Analysis of variance (ANOVA) plus Tukey post hoc tests. Results: Specimens with type C(Remove flask from water bath, bench cool for 10min and then cool under running water for 15min)cooling procedures have high hardness values, among whichLucitone showed better properties. Surface roughness did not show significant changes among different groups. Brushing did not significantly affect surface roughness and hardness of denture base materials. Conclusion: Two of the treatments tested, Treatment C: bench-cooling for 10 min and cooling under running water for 15min and Treatment A: cooling in water-bath till room temperature provided the highest hardness values.

International Journal of Advanced ResearchVol. 12(09)
Openalex Percentile: Top 80%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.