Hydrogel-based fluorescence assay kit for simultaneous determination of ceftazidime and avibactam

Monitoring the concentration of antibiotics rapidly and cost-effectively is crucial for accurate clinical medication and timely identification of drug-induced illnesses. Here, we constructed a novel fluorescent assay kit to monitor Zavicefta, an effective antibiotic composed of avibactam (AVI) and ceftazidime (CFZ) to treat carbapenem-resistant gram-negative bacteria infections. AVI can emit fluorescence, but CFZ cannot. To enable simultaneous measurement of both in one kit, we designed molecularly imprinted polymer (MIP) modified quantum dots (QDs) for CFZ determination. MIPs have received significant attention as an artificial antibody due to their exceptional specificity for various targets, particularly drugs with small molecular weight. Under the excitation wavelength of 350 nm, the detection process involves a decrease in QDs’ fluorescence signal at 600 nm owing to the “gate effect” between MIP and CFZ and the internal filtration effect between CFZ and QDs. Simultaneously, a fluorescence emission characteristic peak at 420 nm for AVI emerges. In addition, to simplify the operation procedure and improve determination throughput, the detection agents were incorporated into a hydrogel and placed in a 96-well plate, enabling concurrent quantification of AVI and CFZ within the respective range of 80–1000 μM and 1–1000 μM. The developed assay kit successfully determined AVI and CFZ in human serums and therapeutic drug monitoring in a live rabbit model. Recoveries of AVI and CFZ were 92.7–114%, with relative standard deviations below 6.0%. Moreover, a smartphone was employed to read the fluorescence signals, which was beneficial for cost reduction and out-of-lab analysis. This study will deliver a pragmatic resolution to developing high-throughput assay kits for drug determination.

Authors

Institutions

Publication Details

Journal
Microchimica Acta
Published
2024-10-16
DOI
https://doi.org/10.1007/s00604-024-06742-1
Citations
1
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.45

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrogel-based fluorescence assay kit for simultaneous determination of ceftazidime and avibactam

Hongping Qu, Johnjoe McFadden, Zheying Tao, B.W. Zhang et al.
1 citations
Microchimica Acta
Antibiotics Pharmacokinetics and Efficacy
0.45
article

Hydrogel-based fluorescence assay kit for simultaneous determination of ceftazidime and avibactam

Hongping Qu, Johnjoe McFadden, Zheying Tao, B.W. Zhang, Jialin Liu, Xiaoli Wang, Lijun Du, Jieming Qu, Jiao Yang, Yingchun Li, Li Zhang
article en
1 citations

Abstract

Monitoring the concentration of antibiotics rapidly and cost-effectively is crucial for accurate clinical medication and timely identification of drug-induced illnesses. Here, we constructed a novel fluorescent assay kit to monitor Zavicefta, an effective antibiotic composed of avibactam (AVI) and ceftazidime (CFZ) to treat carbapenem-resistant gram-negative bacteria infections. AVI can emit fluorescence, but CFZ cannot. To enable simultaneous measurement of both in one kit, we designed molecularly imprinted polymer (MIP) modified quantum dots (QDs) for CFZ determination. MIPs have received significant attention as an artificial antibody due to their exceptional specificity for various targets, particularly drugs with small molecular weight. Under the excitation wavelength of 350 nm, the detection process involves a decrease in QDs’ fluorescence signal at 600 nm owing to the “gate effect” between MIP and CFZ and the internal filtration effect between CFZ and QDs. Simultaneously, a fluorescence emission characteristic peak at 420 nm for AVI emerges. In addition, to simplify the operation procedure and improve determination throughput, the detection agents were incorporated into a hydrogel and placed in a 96-well plate, enabling concurrent quantification of AVI and CFZ within the respective range of 80–1000 μM and 1–1000 μM. The developed assay kit successfully determined AVI and CFZ in human serums and therapeutic drug monitoring in a live rabbit model. Recoveries of AVI and CFZ were 92.7–114%, with relative standard deviations below 6.0%. Moreover, a smartphone was employed to read the fluorescence signals, which was beneficial for cost reduction and out-of-lab analysis. This study will deliver a pragmatic resolution to developing high-throughput assay kits for drug determination.

Microchimica ActaVol. 191(11)
Shanghai Jiao Tong University (CN), Harbin Institute of Technology (CN), Ruijin Hospital (CN), University of Surrey (GB)
Shanghai Municipal Health Commission, Science and Technology Commission of Shanghai Municipality, Shanghai Jiao Tong University, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, National Key Research and Development Program of China
Openalex Percentile: Top 31%
Antibiotics Pharmacokinetics and Efficacy
0.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.