Critical current characteristics and ampere force distribution of a novel HTS cable with different transposition lengths

Abstract Distribution characteristics of the current, ampere force and magnetic flux density (B [T]) of a novel high temperature superconducting (HTS) cable woven by transposed REBCO tapes under different transposition lengths are proposed, and these characteristics of the cable stacked with 3 REBCO tapes are also carried out in this paper for comparison. The objective is to enhance the current density and the compactness of the HTS tapes combination, and uniform the current, ampere force and magnetic flux density (B [T]) distributions. A three-dimensional (3D) finite element model, based on Maxwell’s equations without consideration of the displacement current, is established to describe the state of the system in the liquid nitrogen condition. The distributions characteristics, maximum and minimum values of current, ampere force and magnetic flux density (B [T]) show significant differences in the simulation results between the novel HTS cable woven by 3 transposed REBCO tapes and the cable stacked with 3 REBCO tapes. The simulated results show that the distribution characteristics are improved, with a more uniform distribution characteristic than that of the cable stacked with REBCO tapes. This is due to fully transposed REBCO tapes. In addition, the experimental E–I curve was also reached. The experimental results show that using a shorter transposition length in the cable can improve the critical current. However, a too small transposition length can cause significant damage to the HTS tape, resulting in deformation of the HTS tape and a reduction in the electromagnetic properties of the HTS tape. This affects the critical current of the HTS tape and, ultimately, the critical current of the cable. From the point of view of whether the production process is convenient, meets the requirements of economy and reduces costs, we need to find a suitable transposition length. The measured optimal transposition length is 95 mm for the cable woven by 3 REBCO tapes.

Authors

Institutions

Publication Details

Journal
Superconductor Science and Technology
Published
2024-10-16
DOI
https://doi.org/10.1088/1361-6668/ad8783
Citations
2
Primary Topic
Physics of Superconductivity and Magnetism
Type
article
Field-Weighted Citation Impact
0.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Critical current characteristics and ampere force distribution of a novel HTS cable with different transposition lengths

Shinan Chang, Wei Pi, Heng Zhang, Jingyi Yang
2 citations
Superconductor Science and Technology
Physics of Superconductivity and Magnetism
0.62
article

Critical current characteristics and ampere force distribution of a novel HTS cable with different transposition lengths

Shinan Chang, Wei Pi, Heng Zhang, Jingyi Yang
article en
2 citations

Abstract

Abstract Distribution characteristics of the current, ampere force and magnetic flux density (B [T]) of a novel high temperature superconducting (HTS) cable woven by transposed REBCO tapes under different transposition lengths are proposed, and these characteristics of the cable stacked with 3 REBCO tapes are also carried out in this paper for comparison. The objective is to enhance the current density and the compactness of the HTS tapes combination, and uniform the current, ampere force and magnetic flux density (B [T]) distributions. A three-dimensional (3D) finite element model, based on Maxwell’s equations without consideration of the displacement current, is established to describe the state of the system in the liquid nitrogen condition. The distributions characteristics, maximum and minimum values of current, ampere force and magnetic flux density (B [T]) show significant differences in the simulation results between the novel HTS cable woven by 3 transposed REBCO tapes and the cable stacked with 3 REBCO tapes. The simulated results show that the distribution characteristics are improved, with a more uniform distribution characteristic than that of the cable stacked with REBCO tapes. This is due to fully transposed REBCO tapes. In addition, the experimental E–I curve was also reached. The experimental results show that using a shorter transposition length in the cable can improve the critical current. However, a too small transposition length can cause significant damage to the HTS tape, resulting in deformation of the HTS tape and a reduction in the electromagnetic properties of the HTS tape. This affects the critical current of the HTS tape and, ultimately, the critical current of the cable. From the point of view of whether the production process is convenient, meets the requirements of economy and reduces costs, we need to find a suitable transposition length. The measured optimal transposition length is 95 mm for the cable woven by 3 REBCO tapes.

Superconductor Science and TechnologyVol. 37(12)
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 33%
Physics of Superconductivity and Magnetism
0.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.