Towards cleaner machining: Experimental investigation of collagen-in-water as a novel type of metalworking fluids – A technical feasibility study

Driven by environmental challenges, health concerns and increasing legislative restrictions, a high demand for research regarding alternative metalworking fluids (MWFs) to substitute the conventional mineral oil-containing fluids emerges. In recent years, bio-based fluids have continuously gained attention, as their usage could mitigate the disadvantages of conventionally used fluids, which usually contain mineral oil. Against this background, this research aims to contributing towards biological MWFs by investigating the technical applicability of collagen-in-water fluids through evaluations and comparisons with conventional MWFs. The analyzed bio-based MWF is based on collagen-hydrolysate powder dissolved in water, with collagen acting as a viscosity-increasing additive. The prepared fluids were investigated regarding their viscosity and tribological behavior in cylinder-on-ring experiments as well as tapping-torque tests. Afterwards, first machining experiments were performed for honing and grinding of hardened steel. Force-led cylinder-on-ring experiments show a significant wear reduction, e.g. a value of 13.4 mm 2 at 3 wt.% collagen compared to 33.0 mm 2 with pure distilled water. Wear further decreased with increasing collagen content. At 3 wt.% and again compared to pure water, tapping torque was reduced by 29 % to 181.7 Ncm, no further torque reduction was observed with increasing collagen concentration. In honing, roughness was reduced using collagen-in-water, however, an 8 wt.% collagen fluid resulted in an 18 % reduction in material removal rate compared to honing oil. In internal grinding, an 8 wt.% collagen fluid achieved an R a of approximately 0.8 μm, compared to around 0.55 μm with emulsion. The application results demonstrate a high potential for collagen-in-water fluids, however, adjustments are necessary for obtaining competitive fluids. • Viscosity of collagen-in-water increases with increasing collagen concentration. • Fluids perform well in cylinder-on-ring and tapping-torque tests. • Roughness for honing is reduced for collagen-in-water compared to honing oil. • When grinding, emulsion led to lower roughness compared to collagen-in-water.

Authors

Institutions

Publication Details

Journal
Journal of Cleaner Production
Published
2024-10-16
DOI
https://doi.org/10.1016/j.jclepro.2024.143987
Citations
2
Primary Topic
Collagen: Extraction and Characterization
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards cleaner machining: Experimental investigation of collagen-in-water as a novel type of metalworking fluids – A technical feasibility study

Robar Arafat, Christoph Herrmann, Klaus Dröder, Georg Mahlfeld
2 citations
Journal of Cleaner Production
Collagen: Extraction and Characterization
0.35
article

Towards cleaner machining: Experimental investigation of collagen-in-water as a novel type of metalworking fluids – A technical feasibility study

Robar Arafat, Christoph Herrmann, Klaus Dröder, Georg Mahlfeld
article en
2 citations

Abstract

Driven by environmental challenges, health concerns and increasing legislative restrictions, a high demand for research regarding alternative metalworking fluids (MWFs) to substitute the conventional mineral oil-containing fluids emerges. In recent years, bio-based fluids have continuously gained attention, as their usage could mitigate the disadvantages of conventionally used fluids, which usually contain mineral oil. Against this background, this research aims to contributing towards biological MWFs by investigating the technical applicability of collagen-in-water fluids through evaluations and comparisons with conventional MWFs. The analyzed bio-based MWF is based on collagen-hydrolysate powder dissolved in water, with collagen acting as a viscosity-increasing additive. The prepared fluids were investigated regarding their viscosity and tribological behavior in cylinder-on-ring experiments as well as tapping-torque tests. Afterwards, first machining experiments were performed for honing and grinding of hardened steel. Force-led cylinder-on-ring experiments show a significant wear reduction, e.g. a value of 13.4 mm 2 at 3 wt.% collagen compared to 33.0 mm 2 with pure distilled water. Wear further decreased with increasing collagen content. At 3 wt.% and again compared to pure water, tapping torque was reduced by 29 % to 181.7 Ncm, no further torque reduction was observed with increasing collagen concentration. In honing, roughness was reduced using collagen-in-water, however, an 8 wt.% collagen fluid resulted in an 18 % reduction in material removal rate compared to honing oil. In internal grinding, an 8 wt.% collagen fluid achieved an R a of approximately 0.8 μm, compared to around 0.55 μm with emulsion. The application results demonstrate a high potential for collagen-in-water fluids, however, adjustments are necessary for obtaining competitive fluids. • Viscosity of collagen-in-water increases with increasing collagen concentration. • Fluids perform well in cylinder-on-ring and tapping-torque tests. • Roughness for honing is reduced for collagen-in-water compared to honing oil. • When grinding, emulsion led to lower roughness compared to collagen-in-water.

Journal of Cleaner ProductionVol. 480
Fraunhofer Institute for Surface Engineering and Thin Films (DE), Technische Universität Braunschweig (DE)
Industry, innovation and infrastructure
Openalex Percentile: Top 43%
Collagen: Extraction and Characterization
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.