Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform

• A novel diagnositc method based on isothermal multiple cross displacement amplification and nanoparticle-based lateral flow biosensor was devised for detection of HAdV-3 and HAdV-7. • The new approach exhibited unique advantages of simplicity, speed, and accuracy. • The new nearly equipment-free technique make it a valuable diagnostic tool for timely diagnosis and intervention of HAdV-3 and HAdV-7 infection. Human adenoviruses (HAdV), particularly serotypes 3 and 7 (HAdV-3 and HAdV-7), are significant respiratory pathogens that contribute to high morbidity rates and severe pneumonia in infants and children. The lack of distinct clinical presentations and effective treatments highlights the urgent need for rapid and reliable diagnostic methods for HAdV-3 and HAdV-7. This study devises a novel detection assay, termed HAdV-MCDA-LFB, which combines isothermal multiple cross displacement amplification (MCDA) with a nanoparticle-based lateral flow biosensor (LFB). Targeting the conserved hexon gene, HAdV-MCDA-LFB demonstrated high sensitivity, detecting low to 10 fg of hexon-containing plasmid per reaction without cross-reaction under the optimized conditions. Moreover, HAdV-MCDA-LFB exhibited comparable diagnostic accuracy to real-time PCR in clinical sample analysis, indicating its practical applicability. The whole procedure, including rapid template preparation (15 min), MCDA reaction (40 min at 67 °C) and result interpretation (<5 min), can be completed within one hour. Together, this rapid turnaround time, coupled with its simplicity and accuracy, makes HAdV-MCDA-LFB a promising point-of-care diagnostic tool for HAdV-3 and HAdV-7, particularly in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2024-10-17
DOI
https://doi.org/10.1016/j.snr.2024.100252
Citations
1
Primary Topic
Virus-based gene therapy research
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform

Nan Jia, Juan Zhou, Jin Fu, Li Wan et al.
1 citations
Sensors and Actuators Reports
Virus-based gene therapy research
0.55
article

Rapid detection of human adenovirus by multiple cross displacement amplification combined with nanoparticle-based biosensor platform

Nan Jia, Juan Zhou, Jin Fu, Li Wan, Fei Xiao, Zhu Xiong, Yingxin Zhang, Min Chen, Yi Wang, Shijun Li, Xiaolan Huang
article en
1 citations

Abstract

• A novel diagnositc method based on isothermal multiple cross displacement amplification and nanoparticle-based lateral flow biosensor was devised for detection of HAdV-3 and HAdV-7. • The new approach exhibited unique advantages of simplicity, speed, and accuracy. • The new nearly equipment-free technique make it a valuable diagnostic tool for timely diagnosis and intervention of HAdV-3 and HAdV-7 infection. Human adenoviruses (HAdV), particularly serotypes 3 and 7 (HAdV-3 and HAdV-7), are significant respiratory pathogens that contribute to high morbidity rates and severe pneumonia in infants and children. The lack of distinct clinical presentations and effective treatments highlights the urgent need for rapid and reliable diagnostic methods for HAdV-3 and HAdV-7. This study devises a novel detection assay, termed HAdV-MCDA-LFB, which combines isothermal multiple cross displacement amplification (MCDA) with a nanoparticle-based lateral flow biosensor (LFB). Targeting the conserved hexon gene, HAdV-MCDA-LFB demonstrated high sensitivity, detecting low to 10 fg of hexon-containing plasmid per reaction without cross-reaction under the optimized conditions. Moreover, HAdV-MCDA-LFB exhibited comparable diagnostic accuracy to real-time PCR in clinical sample analysis, indicating its practical applicability. The whole procedure, including rapid template preparation (15 min), MCDA reaction (40 min at 67 °C) and result interpretation (<5 min), can be completed within one hour. Together, this rapid turnaround time, coupled with its simplicity and accuracy, makes HAdV-MCDA-LFB a promising point-of-care diagnostic tool for HAdV-3 and HAdV-7, particularly in resource-limited settings.

Sensors and Actuators ReportsVol. 8
Guizhou Center for Disease Control and Prevention (CN), Capital Institute of Pediatrics (CN), Sanya Central Hospital (CN)
National Natural Science Foundation of China, Beijing Nova Program
Affordable and clean energy
Openalex Percentile: Top 25%
Virus-based gene therapy research
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.