Potensi Pencahayaan Alami pada Bangunan Peribadatan Gereja GPIB Filadelfia Semarang

Natural lighting is one of the supporting functions of space that can positively impact space users. One of the benefits is visual comfort when carrying out various indoor activities. Visual comfort is needed in every room, including the worship room. This study aims to evaluate the intensity of natural lighting in the GPIB Filadelfia Church Semarang church hall. This research uses the quantitative method by doing direct observations and measurements using a lux meter placed at twelve measuring points during sunny weather. The results showed that the average light intensity in the morning, afternoon, and evening complies with the visual comfort standards of SNI 03-6197-2000; thus, overall visual comfort is achieved. However, some measuring points with small lighting intensity are still not up to standards because the location is too far from the openings. A light barrier also affects the difference in light intensity at each measuring point.

Authors

Institutions

Publication Details

Journal
Jurnal Sipil dan Arsitektur
Published
2024-09-30
DOI
https://doi.org/10.14710/pilars.2.3.2024.48-55
Primary Topic
Architectural and Urban Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Potensi Pencahayaan Alami pada Bangunan Peribadatan Gereja GPIB Filadelfia Semarang

Chely Novia Bramiana, Varinca Augi Tahapary
Jurnal Sipil dan Arsitektur
Architectural and Urban Studies
article

Potensi Pencahayaan Alami pada Bangunan Peribadatan Gereja GPIB Filadelfia Semarang

Chely Novia Bramiana, Varinca Augi Tahapary
article en

Abstract

Natural lighting is one of the supporting functions of space that can positively impact space users. One of the benefits is visual comfort when carrying out various indoor activities. Visual comfort is needed in every room, including the worship room. This study aims to evaluate the intensity of natural lighting in the GPIB Filadelfia Church Semarang church hall. This research uses the quantitative method by doing direct observations and measurements using a lux meter placed at twelve measuring points during sunny weather. The results showed that the average light intensity in the morning, afternoon, and evening complies with the visual comfort standards of SNI 03-6197-2000; thus, overall visual comfort is achieved. However, some measuring points with small lighting intensity are still not up to standards because the location is too far from the openings. A light barrier also affects the difference in light intensity at each measuring point.

Jurnal Sipil dan ArsitekturVol. 2(3)
Diponegoro University (ID)
Sustainable cities and communities
Openalex Percentile: Top 74%
Architectural and Urban Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.