Improvement of angle measurement sensitivity using second harmonic wave interference

This paper presents the angular displacement measurement based on second harmonic generation (SHG). In our previous study, the angular resolution of sub-arcsecond was achieved. In this paper, three kinds of sensors based on SHG are reported. In these three sensors, the angular displacement is determined from the intensity of the SHG signal since the SHG is sensitive to the angle of the incident light. Two of these sensors in this study utilize the interference of SHG to improve the sensitivity performance. Comparing with the sensors which have been studied before, interference type sensors in this study allow the femtosecond laser to pass through the nonlinear optical crystal twice, which leads to a significant sensitivity improvement. The principles were verified by both simulation and experiment. In the simulation part, the sensitivities of these three kinds of sensors are compared. In the experiment, the sensitivities were confirmed to be consistent with the simulation. Additionally, the resolution of the presented systems is evaluated and sub-0.1-arcsecond is achieved.

Authors

Publication Details

Journal
Optics Express
Published
2024-10-17
DOI
https://doi.org/10.1364/oe.537872
Citations
4
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of angle measurement sensitivity using second harmonic wave interference

Jiahui Lin, Ryo Sato, Hiraku Matsukuma, Wei Gao et al.
4 citations
Optics Express
Advanced Measurement and Metrology Techniques
0.85
article

Improvement of angle measurement sensitivity using second harmonic wave interference

Jiahui Lin, Ryo Sato, Hiraku Matsukuma, Wei Gao, Kuangyi Li
article en
4 citations

Abstract

This paper presents the angular displacement measurement based on second harmonic generation (SHG). In our previous study, the angular resolution of sub-arcsecond was achieved. In this paper, three kinds of sensors based on SHG are reported. In these three sensors, the angular displacement is determined from the intensity of the SHG signal since the SHG is sensitive to the angle of the incident light. Two of these sensors in this study utilize the interference of SHG to improve the sensitivity performance. Comparing with the sensors which have been studied before, interference type sensors in this study allow the femtosecond laser to pass through the nonlinear optical crystal twice, which leads to a significant sensitivity improvement. The principles were verified by both simulation and experiment. In the simulation part, the sensitivities of these three kinds of sensors are compared. In the experiment, the sensitivities were confirmed to be consistent with the simulation. Additionally, the resolution of the presented systems is evaluated and sub-0.1-arcsecond is achieved.

Optics ExpressVol. 32(23)
Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 30%
Advanced Measurement and Metrology Techniques
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.