Using syringe filtration after lab‐scale adsorption processes potentially overestimates PFAS adsorption removal efficiency from non‐conventional irrigation water

The adsorption process, known for its cost-effectiveness and high efficiency, has been extensively investigated at the laboratory scale for removing per- and polyfluoroalkyl substances (PFAS) from non-conventional irrigation water. However, a syringe filtration step is commonly used when quantifying PFAS removal during this adsorption process, potentially leading to PFAS retention onto the filters and an overestimate of adsorption removal efficiency. Here, we assessed the retention of three prevalent PFAS (i.e., perfluorooctanoic acid [PFOA], perfluorooctane sulfonic acid [PFOS], and perfluorobutanoic acid [PFBA]) on six syringe filters. When filtering distilled deionized water spiked with 1 µg/L and 100 µg/L of each PFAS, we observed the highest and lowest PFAS recovery percentages by mixed cellulose ester (MCE) (0.20 µm, 25 mm; 97 ± 11%, 101 ± 4.8%) and polytetrafluoroethylene (0.45 µm, 13 mm; 61 ± 37%, 80 ± 28%), respectively. Under the initial concentration of 1 µg/L and 100 µg/L, PFOS had recovery percentages of 55 ± 25% and 68 ± 24%, significantly lower than 96 ± 12% and 99 ± 5% for PFOA and 95 ± 8% and 97 ± 4% for PFBA, highlighting the importance of PFAS functional groups. PFAS recovery percentage increased with filtration volume in the order of 80 ± 28% (1 mL) < 85 ± 21% (5 mL) < 90 ± 18% (10 mL). Using MCE to filter treated municipal wastewater spiked with 1 µg/L and 100 µg/L of each PFAS, we found recovery percentages >90% for all three PFAS. Our study underscores the significance of syringe filter selection and potential overestimate of PFAS removal efficacy by the lab-scale adsorption processes.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Quality
Published
2024-10-16
DOI
https://doi.org/10.1002/jeq2.20640
Citations
7
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
1.75

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using syringe filtration after lab‐scale adsorption processes potentially overestimates PFAS adsorption removal efficiency from non‐conventional irrigation water

Huan Chen, Erika Carter, Shiqiang Zou, Alex Chow et al.
7 citations
Journal of Environmental Quality
Per- and polyfluoroalkyl substances research
1.75
article

Using syringe filtration after lab‐scale adsorption processes potentially overestimates PFAS adsorption removal efficiency from non‐conventional irrigation water

Huan Chen, Erika Carter, Shiqiang Zou, Alex Chow, Clinton F. Williams, Yulin Zheng
article en
7 citations

Abstract

The adsorption process, known for its cost-effectiveness and high efficiency, has been extensively investigated at the laboratory scale for removing per- and polyfluoroalkyl substances (PFAS) from non-conventional irrigation water. However, a syringe filtration step is commonly used when quantifying PFAS removal during this adsorption process, potentially leading to PFAS retention onto the filters and an overestimate of adsorption removal efficiency. Here, we assessed the retention of three prevalent PFAS (i.e., perfluorooctanoic acid [PFOA], perfluorooctane sulfonic acid [PFOS], and perfluorobutanoic acid [PFBA]) on six syringe filters. When filtering distilled deionized water spiked with 1 µg/L and 100 µg/L of each PFAS, we observed the highest and lowest PFAS recovery percentages by mixed cellulose ester (MCE) (0.20 µm, 25 mm; 97 ± 11%, 101 ± 4.8%) and polytetrafluoroethylene (0.45 µm, 13 mm; 61 ± 37%, 80 ± 28%), respectively. Under the initial concentration of 1 µg/L and 100 µg/L, PFOS had recovery percentages of 55 ± 25% and 68 ± 24%, significantly lower than 96 ± 12% and 99 ± 5% for PFOA and 95 ± 8% and 97 ± 4% for PFBA, highlighting the importance of PFAS functional groups. PFAS recovery percentage increased with filtration volume in the order of 80 ± 28% (1 mL) < 85 ± 21% (5 mL) < 90 ± 18% (10 mL). Using MCE to filter treated municipal wastewater spiked with 1 µg/L and 100 µg/L of each PFAS, we found recovery percentages >90% for all three PFAS. Our study underscores the significance of syringe filter selection and potential overestimate of PFAS removal efficacy by the lab-scale adsorption processes.

Journal of Environmental QualityVol. 54(1)
Chinese University of Hong Kong (HK), U.S. Arid Land Agricultural Research Center (US), Clemson University (US), Auburn University (US)
National Institute of Food and Agriculture
Clean water and sanitation
Openalex Percentile: Top 17%
Per- and polyfluoroalkyl substances research
1.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.