Development of FPGA-Based Nuclear Electronics Using NI MyRIO Hardware for Small-Scale Radiation Detector Systems

This study presents advancements in coincidence electronics and a pulse height analyzer (PHA) utilizing commercial field-programmable gate array (FPGA)-based hardware for radiation scintillation detectors. The hardware, based on a cost-effective NI myRIO device, integrates an FPGA, ARM Cortex-A9 processor, analog input (AI), digital input and output (DIO), and USB/wireless connectivity with a host computer. LabVIEW codes developed on the LabVIEW platform are implemented in the NI myRIO hardware for seamless integration and interfacing with a computer. The performance of the FPGA-based coincidence electronics is assessed through an experimental setup measuring the gamma-gamma angular distribution of a 22Na radioisotope source. Similarly, the FPGA-based PHA is tested with a CsI(Tl) detector, and its energy resolution is compared to a commercial EASY-MCA 2 K from AMETEK Inc.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-10-16
DOI
https://doi.org/10.1109/tns.2024.3481408
Citations
1
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of FPGA-Based Nuclear Electronics Using NI MyRIO Hardware for Small-Scale Radiation Detector Systems

Trương Thị Hồng Loan, Nguyen Tri Toan Phuc, Vo Hong Hai, Hoàng Thị Kiều Trang et al.
1 citations
IEEE Transactions on Nuclear Science
Radiation Effects in Electronics
0.21
article

Development of FPGA-Based Nuclear Electronics Using NI MyRIO Hardware for Small-Scale Radiation Detector Systems

Trương Thị Hồng Loan, Nguyen Tri Toan Phuc, Vo Hong Hai, Hoàng Thị Kiều Trang, Phan Le Hoang Sang
article en
1 citations

Abstract

This study presents advancements in coincidence electronics and a pulse height analyzer (PHA) utilizing commercial field-programmable gate array (FPGA)-based hardware for radiation scintillation detectors. The hardware, based on a cost-effective NI myRIO device, integrates an FPGA, ARM Cortex-A9 processor, analog input (AI), digital input and output (DIO), and USB/wireless connectivity with a host computer. LabVIEW codes developed on the LabVIEW platform are implemented in the NI myRIO hardware for seamless integration and interfacing with a computer. The performance of the FPGA-based coincidence electronics is assessed through an experimental setup measuring the gamma-gamma angular distribution of a 22Na radioisotope source. Similarly, the FPGA-based PHA is tested with a CsI(Tl) detector, and its energy resolution is compared to a commercial EASY-MCA 2 K from AMETEK Inc.

IEEE Transactions on Nuclear ScienceVol. 72(3)
Ho Chi Minh City University of Science (VN)
Viet Nam National University Ho Chi Minh City
Affordable and clean energy
Openalex Percentile: Top 47%
Radiation Effects in Electronics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.