Grid-Forming Control of DFIG-Based Wind Turbine Generator by Using Internal Voltage Vectors for Asymmetrical Fault Ride-Through

Grid-forming (GFM) controls exhibit robust frequency and voltage support capabilities for inverter-based resources (IBRs). This also shows promise for doubly fed induction generator-based wind turbine generators (DFIG-based WTGs). However, during asymmetrical faults, the DFIG-based WTG that employs GFM controls (GFM-DFIG) might suffer from overcurrent and overmodulation of the rotor-side converter (RSC). Therefore, from the perspective of positive-sequence, negative-sequence, and transient components, this paper proposes asymmetrical fault ride-through (FRT) controls for the GFM-DFIG based on the mechanism for forming the grid voltage. Firstly, internal voltage vectors are designed for the assessment of asymmetrical FRT capabilities. Then a positive- and negative-sequence control (PNSC) is proposed to support the sequence components of internal voltage vectors for the GFM-DFIG. On this basis, an asymmetrical FRT control structure is proposed, incorporating negative-sequence reactive current injection and two types of positive-sequence control schemes: the current saturation-based method and virtual impedance-based method. Additionally, a simplified calculation method for transient voltages is utilized to eliminate the impacts of transient flux leakage. Finally, the proposed FRT controls for the GFM-DFIG are validated by using the EPRI benchmark system. The results indicate that, with the proposed control, GFM-DFIG can maintain stable voltages and achieve required negative-sequence behaviors.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Energy Conversion
Published
2024-10-16
DOI
https://doi.org/10.1109/tec.2024.3470588
Citations
7
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid-Forming Control of DFIG-Based Wind Turbine Generator by Using Internal Voltage Vectors for Asymmetrical Fault Ride-Through

Yuanzhu Chang, Ilhan Koçar, Xinquan Chen
7 citations
IEEE Transactions on Energy Conversion
Wind Turbine Control Systems
1.46
article

Grid-Forming Control of DFIG-Based Wind Turbine Generator by Using Internal Voltage Vectors for Asymmetrical Fault Ride-Through

Yuanzhu Chang, Ilhan Koçar, Xinquan Chen
article en
7 citations

Abstract

Grid-forming (GFM) controls exhibit robust frequency and voltage support capabilities for inverter-based resources (IBRs). This also shows promise for doubly fed induction generator-based wind turbine generators (DFIG-based WTGs). However, during asymmetrical faults, the DFIG-based WTG that employs GFM controls (GFM-DFIG) might suffer from overcurrent and overmodulation of the rotor-side converter (RSC). Therefore, from the perspective of positive-sequence, negative-sequence, and transient components, this paper proposes asymmetrical fault ride-through (FRT) controls for the GFM-DFIG based on the mechanism for forming the grid voltage. Firstly, internal voltage vectors are designed for the assessment of asymmetrical FRT capabilities. Then a positive- and negative-sequence control (PNSC) is proposed to support the sequence components of internal voltage vectors for the GFM-DFIG. On this basis, an asymmetrical FRT control structure is proposed, incorporating negative-sequence reactive current injection and two types of positive-sequence control schemes: the current saturation-based method and virtual impedance-based method. Additionally, a simplified calculation method for transient voltages is utilized to eliminate the impacts of transient flux leakage. Finally, the proposed FRT controls for the GFM-DFIG are validated by using the EPRI benchmark system. The results indicate that, with the proposed control, GFM-DFIG can maintain stable voltages and achieve required negative-sequence behaviors.

IEEE Transactions on Energy ConversionVol. 40(3)
Hong Kong Polytechnic University (HK), Polytechnique Montréal (CA)
Affordable and clean energy
Openalex Percentile: Top 17%
Wind Turbine Control Systems
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Grid-Forming Control of DFIG-Based Wind Turbine Generator by Using Internal Voltage Vectors for Asymmetrical Fault Ride-Through — Yuanzhu Chang, Ilhan Koçar, et al. · IEEE Transactions on Energy Conversion (2024) | TGRS Research Map | TGRS