A Simple and Accurate PPG Systolic Peak Detector Based on Fractional Order Calculus

Accurate detection of systolic peaks in photoplethysmogram (PPG) signals using simple algorithms is crucial for many healthcare monitoring systems, especially in wearable devices. This paper presents a simple yet accurate systolic peak detector that employs a fractional-order calculus-based filter, performing both noise removal and inflection/extrema point detection in a single stage. The proposed filter can detect inflection and extrema points even in highly noisy PPG signals. By correctly detecting systolic peaks, other fiducial points can be easily identified and subsequent accurate measurements such as heart rate can be obtained. The proposed method was validated on the CapnoBase benchmark dataset, demonstrating an overall accuracy sensitivity, precision and F1-Score of 99.62%, 99.89%, 99.52%, 99.70% respectively for a tolerance interval of 30 ms. These results are comparable to those achieved with state-of-the-art methods, while the proposed method offers the advantage of simpler implementation.

Authors

Institutions

Publication Details

Published
2024-09-21
DOI
https://doi.org/10.1109/idap64064.2024.10710684
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple and Accurate PPG Systolic Peak Detector Based on Fractional Order Calculus

F. Abdelliche, Salah Ferdi
1 citations
Sensor Technology and Measurement Systems
0.35
article

A Simple and Accurate PPG Systolic Peak Detector Based on Fractional Order Calculus

F. Abdelliche, Salah Ferdi
article en
1 citations

Abstract

Accurate detection of systolic peaks in photoplethysmogram (PPG) signals using simple algorithms is crucial for many healthcare monitoring systems, especially in wearable devices. This paper presents a simple yet accurate systolic peak detector that employs a fractional-order calculus-based filter, performing both noise removal and inflection/extrema point detection in a single stage. The proposed filter can detect inflection and extrema points even in highly noisy PPG signals. By correctly detecting systolic peaks, other fiducial points can be easily identified and subsequent accurate measurements such as heart rate can be obtained. The proposed method was validated on the CapnoBase benchmark dataset, demonstrating an overall accuracy sensitivity, precision and F1-Score of 99.62%, 99.89%, 99.52%, 99.70% respectively for a tolerance interval of 30 ms. These results are comparable to those achieved with state-of-the-art methods, while the proposed method offers the advantage of simpler implementation.

National Polytechnic School (EC)
Affordable and clean energy
Openalex Percentile: Top 38%
Sensor Technology and Measurement Systems
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.