An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing

This paper presents a 9-mW ultrasonic through-transmission transceiver (TRX) for portable, non-invasive intracranial pressure (ICP) sensing. It employs two ultrasound transducers placed at the temporal bone windows to measure changes in the ultrasonic time-of-flight (ToF), based on which the skull expansion and the corresponding ICP waveform are derived. Key components include a high-efficiency Class-DE power amplifier (PA) with 95% efficiency and an output swing of 15.8 , along with a successive approximation register (SAR) delay-locked loop (DLL)-based time-to-digital converter (TDC) with 29.8 ps resolution and 122 ns range. Other than electrical characterization, the sensor is validated through two demonstrations using a water tank setup and a human head phantom setup, respectively. It demonstrates a high correlation of with a medical-grade invasive ICP sensor. The proposed system offers high accuracy, low power consumption, and reliable performance, making it a promising solution for real-time, portable, non-invasive ICP monitoring in various clinical settings.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2024-10-16
DOI
https://doi.org/10.1109/tbcas.2024.3481414
Citations
2
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing

Taiyun Chi, Matt Y. Cheung, Ashok Veeraraghavan, Mohammad Hirzallah et al.
2 citations
IEEE Transactions on Biomedical Circuits and Systems
Atomic and Subatomic Physics Research
0.68
article

An Ultrasonic Transceiver for Non-Invasive Intracranial Pressure Sensing

Taiyun Chi, Matt Y. Cheung, Ashok Veeraraghavan, Mohammad Hirzallah, Gerald Topalli, Yingying Fan
article en
2 citations

Abstract

This paper presents a 9-mW ultrasonic through-transmission transceiver (TRX) for portable, non-invasive intracranial pressure (ICP) sensing. It employs two ultrasound transducers placed at the temporal bone windows to measure changes in the ultrasonic time-of-flight (ToF), based on which the skull expansion and the corresponding ICP waveform are derived. Key components include a high-efficiency Class-DE power amplifier (PA) with 95% efficiency and an output swing of 15.8 , along with a successive approximation register (SAR) delay-locked loop (DLL)-based time-to-digital converter (TDC) with 29.8 ps resolution and 122 ns range. Other than electrical characterization, the sensor is validated through two demonstrations using a water tank setup and a human head phantom setup, respectively. It demonstrates a high correlation of with a medical-grade invasive ICP sensor. The proposed system offers high accuracy, low power consumption, and reliable performance, making it a promising solution for real-time, portable, non-invasive ICP monitoring in various clinical settings.

IEEE Transactions on Biomedical Circuits and SystemsVol. 18(6)
Rice University (US)
Climate action
Openalex Percentile: Top 30%
Atomic and Subatomic Physics Research
0.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.