A fault location method for flexible HVDC transmission lines using the linear interpolation

It is difficult to accurately calibrate the traveling wave head and calculate the wave velocity by using the single-ended traveling wave location method. In this paper, a dynamic first traveling wave energy that varies with the fault distance by deeply analyzing the attenuation characteristics of the line transmission function on each first traveling wave frequency component. The maximum first traveling wave energy, namely the main frequency component, monotonically decays with the increase of fault distance, showing a one-to-one mapping relationship with the fault distance. On this basis, this paper proposes a single-ended fault location method for flexible HVDC transmission lines using the linear interpolation. The positioning results are calculated using the linear interpolation method on the distance-initial traveling wave main frequency component curve. The simulation results show that the proposed positioning method eliminates the dependence of traditional single-ended traveling wave positioning methods on the wave head calibration and the wave velocity calculation. The absolute positioning error is less than 0.6km, and the positioning result is not affected by transition resistance.

Authors

Institutions

Publication Details

Published
2024-10-16
DOI
https://doi.org/10.1117/12.3033479
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fault location method for flexible HVDC transmission lines using the linear interpolation

Hang Zhong
HVDC Systems and Fault Protection
article

A fault location method for flexible HVDC transmission lines using the linear interpolation

Hang Zhong
article en

Abstract

It is difficult to accurately calibrate the traveling wave head and calculate the wave velocity by using the single-ended traveling wave location method. In this paper, a dynamic first traveling wave energy that varies with the fault distance by deeply analyzing the attenuation characteristics of the line transmission function on each first traveling wave frequency component. The maximum first traveling wave energy, namely the main frequency component, monotonically decays with the increase of fault distance, showing a one-to-one mapping relationship with the fault distance. On this basis, this paper proposes a single-ended fault location method for flexible HVDC transmission lines using the linear interpolation. The positioning results are calculated using the linear interpolation method on the distance-initial traveling wave main frequency component curve. The simulation results show that the proposed positioning method eliminates the dependence of traditional single-ended traveling wave positioning methods on the wave head calibration and the wave velocity calculation. The absolute positioning error is less than 0.6km, and the positioning result is not affected by transition resistance.

Changsha University of Science and Technology (CN)
Openalex Percentile: Top 84%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A fault location method for flexible HVDC transmission lines using the linear interpolation — Hang Zhong · (2024) | TGRS Research Map | TGRS