Evaluasi Sistem Evakuasi Kebakaran pada Kantor Wilayah Direktorat Jenderal Bea Cukai Kalimantan Bagian Selatan

Banjarmasin is one of Indonesia’s ten provinces that are historically prone to fire. To prevent many life losses due to building fire, a building must comply with existing standards and regulations. Therefore, the fire evacuation system was evaluated at the South Kalimantan Regional Office of the Directorate General of Customs. In this research, the method used is descriptive with an evaluative analysis approach where the building data will be compared to related standards and regulations. From this research, it is proven that several fire evacuation system facilities in the building still do not comply with the existing standards and regulations, such as the number of emergency stairs, emergency exits, and the height of handrails on the stairs.

Authors

Institutions

Publication Details

Journal
Jurnal Sipil dan Arsitektur
Published
2024-09-30
DOI
https://doi.org/10.14710/pilars.2.3.2024.56-61
Primary Topic
Economic Growth and Fiscal Policies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluasi Sistem Evakuasi Kebakaran pada Kantor Wilayah Direktorat Jenderal Bea Cukai Kalimantan Bagian Selatan

Hermin Werdiningsih, Yasmine Adzkia
Jurnal Sipil dan Arsitektur
Economic Growth and Fiscal Policies
article

Evaluasi Sistem Evakuasi Kebakaran pada Kantor Wilayah Direktorat Jenderal Bea Cukai Kalimantan Bagian Selatan

Hermin Werdiningsih, Yasmine Adzkia
article en

Abstract

Banjarmasin is one of Indonesia’s ten provinces that are historically prone to fire. To prevent many life losses due to building fire, a building must comply with existing standards and regulations. Therefore, the fire evacuation system was evaluated at the South Kalimantan Regional Office of the Directorate General of Customs. In this research, the method used is descriptive with an evaluative analysis approach where the building data will be compared to related standards and regulations. From this research, it is proven that several fire evacuation system facilities in the building still do not comply with the existing standards and regulations, such as the number of emergency stairs, emergency exits, and the height of handrails on the stairs.

Jurnal Sipil dan ArsitekturVol. 2(3)
Diponegoro University (ID)
Openalex Percentile: Top 78%
Economic Growth and Fiscal Policies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.