Development of micro/nano-tomography system at SPring-8 BL47XU

X-ray micro/nano-tomography (multiscale CT) has been developed at SPring-8 BL47XU. The x-ray optics consists of a simple projection type imaging system for micro-tomography and a full-field x-ray microscope using a Fresnel zone plate (FZP) for nano-tomography, respectively. All components are mounted on high precision stages driven by stepper motor. It takes two or three minutes to change the mode from “micro” to “nano” or “nano” to “micro”. The spatial resolutions are 1μm and 100nm for micro and nano tomography. The width of the field of views are 800μm and 60μm. The measurement time is about 2 minutes for 1800 projections in nano-mode. The sample stages also have a possibility to switch to the setup of laminography measurement mode. The energy range is between 7keV and 15keV for multiscale CT.

Authors

Institutions

Publication Details

Published
2024-10-17
DOI
https://doi.org/10.1117/12.3027966
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of micro/nano-tomography system at SPring-8 BL47XU

Kentaro Uesugi, Masahiro Yasutake, Akihisa Takeuchi
Nuclear Physics and Applications
article

Development of micro/nano-tomography system at SPring-8 BL47XU

Kentaro Uesugi, Masahiro Yasutake, Akihisa Takeuchi
article en

Abstract

X-ray micro/nano-tomography (multiscale CT) has been developed at SPring-8 BL47XU. The x-ray optics consists of a simple projection type imaging system for micro-tomography and a full-field x-ray microscope using a Fresnel zone plate (FZP) for nano-tomography, respectively. All components are mounted on high precision stages driven by stepper motor. It takes two or three minutes to change the mode from “micro” to “nano” or “nano” to “micro”. The spatial resolutions are 1μm and 100nm for micro and nano tomography. The width of the field of views are 800μm and 60μm. The measurement time is about 2 minutes for 1800 projections in nano-mode. The sample stages also have a possibility to switch to the setup of laminography measurement mode. The energy range is between 7keV and 15keV for multiscale CT.

Japan Synchrotron Radiation Research Institute (JP)
Openalex Percentile: Top 74%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.