The biocompatibility of gallium-based liquid metals with blood and serum

Excellent biocompatibility of liquid metals is the basis for developing biomedical applications, such as implantable devices, drug delivery, and tumor therapy. Especially, a systematic study to reveal the influence of gallium-based liquid metals on the composition of blood while they are used in the human body is vital but missing. Here, the compatibility of three kinds of frequently used gallium-based liquid metals with human blood and serum was explored systematically. The results show that treating blood and serum with gallium-based liquid metals did not cause hemolysis, suggesting red blood cells are not damaged or ruptured, and treatment had a negligible effect on the components in the blood. Additionally, the serum levels of glucose, cholesterol, and liver function molecules showed no change after adding liquid metals. These findings suggest that liquid metals have high compatibility with human blood and serum and are conductive to be applied in the fields of biomedical engineering.

Authors

Institutions

Publication Details

Journal
iScience
Published
2024-10-16
DOI
https://doi.org/10.1016/j.isci.2024.111183
Citations
13
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
2.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The biocompatibility of gallium-based liquid metals with blood and serum

Hongzhang Wang, Junhang Ding, Yubo Fan, Yongliang Wang et al.
13 citations
iScience
Bone Tissue Engineering Materials
2.40
article

The biocompatibility of gallium-based liquid metals with blood and serum

Hongzhang Wang, Junhang Ding, Yubo Fan, Yongliang Wang, Jie Zhang, Yudong Wu, Xinpeng Wang, Zhao-Xia Qi, Yingying He
article en
13 citations

Abstract

Excellent biocompatibility of liquid metals is the basis for developing biomedical applications, such as implantable devices, drug delivery, and tumor therapy. Especially, a systematic study to reveal the influence of gallium-based liquid metals on the composition of blood while they are used in the human body is vital but missing. Here, the compatibility of three kinds of frequently used gallium-based liquid metals with human blood and serum was explored systematically. The results show that treating blood and serum with gallium-based liquid metals did not cause hemolysis, suggesting red blood cells are not damaged or ruptured, and treatment had a negligible effect on the components in the blood. Additionally, the serum levels of glucose, cholesterol, and liver function molecules showed no change after adding liquid metals. These findings suggest that liquid metals have high compatibility with human blood and serum and are conductive to be applied in the fields of biomedical engineering.

iScienceVol. 27(11)
Qingdao University (CN), Tsinghua–Berkeley Shenzhen Institute (CN), First Institute of Oceanography (CN), Affiliated Hospital of Qingdao University (CN), Beihang University (CN), Tsinghua University (CN)
Ministry of Natural Resources of the People's Republic of China, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Shandong Provincial Finance Department
Openalex Percentile: Top 11%
Bone Tissue Engineering Materials
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.