Mechanical Failure of Modular Rotating Hinge Femoral Component

Hinge constructs can be used in revision total knee arthroplasty in cases of major collateral ligament deficiency, global knee instability, repeated failure of constrained implants, or large bone defects. Although the success of this construct in revision total knee arthroplasty varies depending on the type of surgery and bone quality, hinged implants can solve a wide array of complex problems while preserving stable flexion-extension motion for ambulation. The most common reasons for re-revision include patellofemoral complications, aseptic loosening, and infection. Most cases of mechanical failure for these hinged constructs occur at the hinge component. Here, we report the first instance of catastrophic femoral component failure in a modular rotating hinge via a low-energy mechanism.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2024-10-16
DOI
https://doi.org/10.1016/j.artd.2024.101495
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Failure of Modular Rotating Hinge Femoral Component

Sean P. Ryan, Michael P. Bolognesi, Samuel S. Wellman, Thorsten M. Seyler et al.
Arthroplasty Today
Orthopaedic implants and arthroplasty
article

Mechanical Failure of Modular Rotating Hinge Femoral Component

Sean P. Ryan, Michael P. Bolognesi, Samuel S. Wellman, Thorsten M. Seyler, Justin Leal, Rahul Goel
article en

Abstract

Hinge constructs can be used in revision total knee arthroplasty in cases of major collateral ligament deficiency, global knee instability, repeated failure of constrained implants, or large bone defects. Although the success of this construct in revision total knee arthroplasty varies depending on the type of surgery and bone quality, hinged implants can solve a wide array of complex problems while preserving stable flexion-extension motion for ambulation. The most common reasons for re-revision include patellofemoral complications, aseptic loosening, and infection. Most cases of mechanical failure for these hinged constructs occur at the hinge component. Here, we report the first instance of catastrophic femoral component failure in a modular rotating hinge via a low-energy mechanism.

Arthroplasty TodayVol. 30
Duke University Hospital (US)
Openalex Percentile: Top 67%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanical Failure of Modular Rotating Hinge Femoral Component — Sean P. Ryan, Michael P. Bolognesi, et al. · Arthroplasty Today (2024) | TGRS Research Map | TGRS