Variability of low frequency laboratory measurements of acoustic isolation of floor/ceiling assemblies

It has long been recognized that building acoustics measurements performed in laboratories exhibit a high degree of variability between and within labs. Traditional metrics limited the use of data to above the 100Hz or 125Hz one-third octave bands. In recent years, focus has widened the range of frequencies of interest to the 50Hz one-third octave band or lower. Analyzing measurements of low frequencies in buildings is complicated by the physical reality of wavelengths that are similar in scale to common room dimensions resulting in modal behavior and the mathematical simplification of the wave equation in building acoustic calculations that assumes a diffuse field which discounts both phase and angle of incidence. Evaluation of common building isolation measurements of the same test floor/ceiling structure sample in the same lab and between labs across the frequency spectrum allows the comparison of the repeatability and reproducibility at low frequency ranges to those at high frequency ranges. Measurements and their associated metrics of various sources, including pink noise produced by loudspeakers, the standard tapping machine, and the impact ball are included in the analysis.

Authors

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3400
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variability of low frequency laboratory measurements of acoustic isolation of floor/ceiling assemblies

Evelyn Way
NOISE-CON proceedings
Acoustic Wave Phenomena Research
article

Variability of low frequency laboratory measurements of acoustic isolation of floor/ceiling assemblies

Evelyn Way
article en

Abstract

It has long been recognized that building acoustics measurements performed in laboratories exhibit a high degree of variability between and within labs. Traditional metrics limited the use of data to above the 100Hz or 125Hz one-third octave bands. In recent years, focus has widened the range of frequencies of interest to the 50Hz one-third octave band or lower. Analyzing measurements of low frequencies in buildings is complicated by the physical reality of wavelengths that are similar in scale to common room dimensions resulting in modal behavior and the mathematical simplification of the wave equation in building acoustic calculations that assumes a diffuse field which discounts both phase and angle of incidence. Evaluation of common building isolation measurements of the same test floor/ceiling structure sample in the same lab and between labs across the frequency spectrum allows the comparison of the repeatability and reproducibility at low frequency ranges to those at high frequency ranges. Measurements and their associated metrics of various sources, including pink noise produced by loudspeakers, the standard tapping machine, and the impact ball are included in the analysis.

NOISE-CON proceedingsVol. 270(7)
Sustainable cities and communities
Openalex Percentile: Top 83%
Acoustic Wave Phenomena Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.