Reliable metrology for infrasound sensors

The reliable assessment of infrasound has become increasingly important in the last years. Reliable measurements require calibration of the employed sensors with traceability to the SI. While there is measurement equipment capable of measuring infrasound available, there is no sufficient calibration below 10 Hz. Traceability for airborne sound is currently realized by primary calibration methods which are applicable down to 2 Hz, with limitations below 10 Hz. Against that background, a primary and a secondary calibration setup have been developed at PTB. Together they enable the traceable calibration of a variety of infrasound sensors such as microphones, sound level meters or microbarometers. Moreover in practice, procedures are necessary which ensure reliable results in a field environment even with external disturbances. A field study was conducted comparing the performance of measurement microphones and microbarometers at a wind park. Emphasis was placed on different means of protection against wind induced noise. Additionally, a laboratory study investigated the influence of small damages to a microphone diaphragm on the reliability of the microphone. In this contribution, the newly developed calibration setups for infrasound sensors and the insights from the field and laboratory studies are presented.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3515
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliable metrology for infrasound sensors

Christoph Kling, Christian Koch, M. Rust
NOISE-CON proceedings
Seismic Waves and Analysis
article

Reliable metrology for infrasound sensors

Christoph Kling, Christian Koch, M. Rust
article en

Abstract

The reliable assessment of infrasound has become increasingly important in the last years. Reliable measurements require calibration of the employed sensors with traceability to the SI. While there is measurement equipment capable of measuring infrasound available, there is no sufficient calibration below 10 Hz. Traceability for airborne sound is currently realized by primary calibration methods which are applicable down to 2 Hz, with limitations below 10 Hz. Against that background, a primary and a secondary calibration setup have been developed at PTB. Together they enable the traceable calibration of a variety of infrasound sensors such as microphones, sound level meters or microbarometers. Moreover in practice, procedures are necessary which ensure reliable results in a field environment even with external disturbances. A field study was conducted comparing the performance of measurement microphones and microbarometers at a wind park. Emphasis was placed on different means of protection against wind induced noise. Additionally, a laboratory study investigated the influence of small damages to a microphone diaphragm on the reliability of the microphone. In this contribution, the newly developed calibration setups for infrasound sensors and the insights from the field and laboratory studies are presented.

NOISE-CON proceedingsVol. 270(7)
Physikalisch-Technische Bundesanstalt (DE)
Affordable and clean energy
Openalex Percentile: Top 82%
Seismic Waves and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.