Heavy-weight impact sound insulation characteristics related with vibrational properties of Korean domestic CLT slabs with different species and joint types

Korea has the world's most strict inter-floor noise regulations. In order to build an apartment house with more than 30 units, it must meet the minimum requirement of impact sound level, single number quantities of 49 dB. These regulations make it hard to expand residential tall wood building in Korea. For making quality satisfied CLT floors, as the preliminary investigations, the effects of wood species and CLT panel joints on the vibration and sound insulation performance of CLT were analyzed. The natural frequency range of the CLT slabs is from 20 Hz to 22 Hz. There were no significant differences depending on wood species and CLT panel joint type. As the stiffness of the slabs increased, the floor impact sound insulation performance also improved. The deflection model for CLT slabs was developed and validated with the actual deflection derived by acceleration spectrum. The measured value was 62 ~ 87% of the predicted value.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2024-10-04
DOI
https://doi.org/10.3397/in_2024_3406
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heavy-weight impact sound insulation characteristics related with vibrational properties of Korean domestic CLT slabs with different species and joint types

Sung-Jun Pang, Sang-Joon Lee, Hyo‐Jin Lee, Yeon-su Ha
NOISE-CON proceedings
Structural Analysis of Composite Materials
article

Heavy-weight impact sound insulation characteristics related with vibrational properties of Korean domestic CLT slabs with different species and joint types

Sung-Jun Pang, Sang-Joon Lee, Hyo‐Jin Lee, Yeon-su Ha
article en

Abstract

Korea has the world's most strict inter-floor noise regulations. In order to build an apartment house with more than 30 units, it must meet the minimum requirement of impact sound level, single number quantities of 49 dB. These regulations make it hard to expand residential tall wood building in Korea. For making quality satisfied CLT floors, as the preliminary investigations, the effects of wood species and CLT panel joints on the vibration and sound insulation performance of CLT were analyzed. The natural frequency range of the CLT slabs is from 20 Hz to 22 Hz. There were no significant differences depending on wood species and CLT panel joint type. As the stiffness of the slabs increased, the floor impact sound insulation performance also improved. The deflection model for CLT slabs was developed and validated with the actual deflection derived by acceleration spectrum. The measured value was 62 ~ 87% of the predicted value.

NOISE-CON proceedingsVol. 270(7)
Chonnam National University Hospital (KR), Institute of Forest Science (RU)
Life in Land, Sustainable cities and communities
Openalex Percentile: Top 82%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Heavy-weight impact sound insulation characteristics related with vibrational properties of Korean domestic CLT slabs with different species and joint types — Sung-Jun Pang, Sang-Joon Lee, et al. · NOISE-CON proceedings (2024) | TGRS Research Map | TGRS